Polyclinic ÜTS Registration: Health Service Provider Registration, Inventory and Service Procurement

A polyclinic opened by physicians is a health service provider that uses many fixed-asset devices and can procure imaging or laboratory services from outside. In ÜTS, unlike sales centers, a polyclinic makes inventory, usage and consumption notifications and approves the contracts of medical service providers. This page explains the polyclinic's ÜTS registration and obligations with the text of the legislation.

How a polyclinic appears in the legislation

The Regulation on Sale, Advertising and Promotion of Medical Devices mentions polyclinics in two places. The first is the building restriction exception:

"A sales center cannot be opened in a building that houses a healthcare institution or organization, including its garden and annexes, except for buildings that contain polyclinics and practices opened by physicians and dentists, laboratory diagnostic centers that provide only analysis and imaging services, pharmacies, opticianry establishments, hearing aid centers, custom-made prosthesis and orthosis centers and dental prosthesis laboratories."

Source: Medical Device Sales, Advertising and Promotion Regulation (RG 29001), Article 34, paragraph 1.

The second is the limit placed on the promotion activity of sales centers:

"Devices cannot be promoted in emergency services or in polyclinics during patient admission hours."

Source: Medical Device Sales, Advertising and Promotion Regulation (RG 29001), Article 11, paragraph 2 subparagraph (c).

In both provisions, the polyclinic is the party that uses the device, not the one that sells it. The Regulation defines this party as a health service provider:

"Health service provider: natural persons and public and private law legal entities, and their branches without legal personality, that provide health services, produce them and/or temporarily provide a medical device to a patient provided that ownership remains with them,"

Source: Medical Device Sales, Advertising and Promotion Regulation (RG 29001), Article 4, paragraph 1 subparagraph (k).

 

Under which company type is a polyclinic registered in ÜTS

Health institutions are registered in ÜTS as 'Health Service Provider' (ÜTS Registration Guide Article 29/1). Because the license of a private polyclinic is kept in ÇKYS by the provincial health directorate, the ÜTS record is linked to ÇKYS and the responsible manager is pulled from there:

"First of all, the responsible manager of the company must also be defined as the responsible manager in the ÇKYS service. For this, company officials need to talk to the provincial health directorates and have their new manager added to the Agency."

Source: ÜTS User and Company Operations Help Guide, Question A6-1.

If the polyclinic is established as a company, the ÜTS record is MERSİS-based and the signatory must be defined in MERSİS:

"First of all, the signatory of the company must also be defined as a signatory in the MERSİS service."

Source: ÜTS User and Company Operations Help Guide, Question A2-1.

For MERSİS-based companies with a ÇKYS license, the title, address and tax number information is pulled from the ÇKYS service instead of MERSİS (ÜTS User and Company Operations Guide, Question B5-1). When the responsible manager or address changes, ÇKYS is updated first:

"When the responsible manager, title and address of the company change, if the relevant information is updated in ÇKYS, these changes are updated automatically in ÜTS."

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 5, paragraph 7.

 

Does a polyclinic need a sales center authorization certificate

No. A polyclinic does not sell devices; under Article 5/1, the authorization certificate is for those who want to be authorized as a sales center. If a polyclinic wants to sell medical devices to patients, it can do so only with a separate sales center authorization certificate, and under Article 34 this sales center can be opened in a building that has a polyclinic.

An ÜTS record is still mandatory; sales centers cannot sell devices other than Annex-3 devices to places not registered in ÜTS:

"Except for the places specified in the guide published by the Agency, sales centers are prohibited from selling devices, other than the devices in Annex-3, to places not registered in the Agency's registration and information management system."

Source: Medical Device Sales, Advertising and Promotion Regulation (RG 29001), Article 26, paragraph 7.

 

Mandatory ÜTS notifications of a polyclinic

 

NotificationWhenBasisInventory NotificationFor fixed-asset devices subject to maintenance and calibration, such as ultrasound, ECG, patient monitor and autoclaveIndividual Movement Guide Article 8/1Receipt NotificationWhen consumables and devices coming from a sales center are receivedIndividual Movement Guide Article 10/1Usage NotificationWhen an implanted or SUT-matched device that must be associated with the patient is usedIndividual Movement Guide Article 12/1Consumption NotificationWhen a consumable for which no usage notification is made is consumedIndividual Movement Guide Article 13/1Temporary Use Supply NotificationWhen a device is given to a patient for a temporary periodIndividual Movement Guide Article 20/1Service Procurement Contract ApprovalWhen imaging or laboratory services are procured from outsideIndividual Movement Guide ANNEX-3, step 6Write-off/Loss NotificationFor products that complete their economic life or are lostIndividual Movement Guide Article 15/1

 

"Inventory notification is made in ÜTS by health service providers and medical service providers for fixed-asset medical devices within health service providers and medical service providers that are subject to maintenance, repair and calibration."

Source: Guide on ÜTS Individual Movement Notifications of Medical Devices, Article 8, paragraph 1.

"For an inventory notification to be made, the product number (product barcode) must be known and this product number must be defined in ÜTS or in the TİTUBB system."

Source: Individual Movement Notifications Guide ANNEX-1 (Inventory Notification), ANNEX-1, introduction.

For an inventory notification, the product number must be defined in ÜTS; if it is not defined, the product number is first called from the TİTUBB record (Article 8/4). An inventory notification is not made with a lot number (Article 8/2).

"For individual products given to a patient temporarily by an institution/company/hospital, a “Temporary Use Supply Notification” is made."

Source: Guide on ÜTS Individual Movement Notifications of Medical Devices, Article 20, paragraph 1.

 

Imaging and laboratory services procured from outside

Polyclinics can procure services in exchange for consumables or results. In this case the device stock does not pass to the polyclinic; the company providing the service registers as a medical service provider and opens a contract in ÜTS:

"Companies that provide services to health service providers in fields such as imaging, laboratory and dialysis through methods such as consumable/kit-based or result-based payment must have a company record in ÜTS as a Medical Service Provider."

Source: Guide on ÜTS Individual Movement Notifications of Medical Devices, Article 32, paragraph 1.

"The individual stocks in ÜTS of the medical devices used in transactions made by medical service provider companies will in no way be transferred to the health service provider, and the process will be managed through information on which device is used where and within which service."

Source: Individual Movement Notifications Guide ANNEX-3 (Medical Service Providers), ANNEX-3, introduction.

The only action the polyclinic must take is to approve the contract:

"After the medical service provider company adds a contract, the health service provider must approve the contract to which it has been added."

Source: Individual Movement Notifications Guide ANNEX-3 (Medical Service Providers), ANNEX-3, step 6.

"Any user of the health service provider who is a signatory, hospital manager or authorized user type can approve this contract."

Source: Individual Movement Notifications Guide ANNEX-3 (Medical Service Providers), ANNEX-3, step 6, Note 1.

For the side of the company providing the service, see the medical service provider ÜTS registration page.tıbbi hizmet sağlayıcısı ÜTS kaydı sayfasına bakın.

 

Prerequisite documents and users

  • Polyclinic license from the provincial health directorate and ÇKYS record (Question A6-1).
  • MERSİS number and the signatory defined in MERSİS (Question A2-1).
  • Responsible manager defined in ÇKYS; if the field comes up empty from ÇKYS, the application cannot be completed (Situation 12).
  • Product number, serial number and acquisition date of fixed-asset devices (ANNEX-1, Article 8/2).
  • Signatory, hospital manager or authorized user who will approve the service procurement contract (ANNEX-3, Note 1).

 

Common mistakes

  • Not making an inventory notification for fixed-asset devices (Article 8/1).
  • Trying to make an inventory notification with a lot number; it is made only with a serial number (Article 8/2).
  • Taking the device of the company providing the service into the polyclinic's inventory; the individual stock of a medical service provider is not transferred to the health service provider (ANNEX-3).
  • Not approving the contract opened by the medical service provider; the company cannot make a consumption notification (ANNEX-3, step 6).
  • Not having a change of responsible manager made in ÇKYS first (Question A6-1, Registration Guide Article 5/7).
  • Allowing sales center promotion in the polyclinic during patient admission hours (Article 11/2-c).

 

Related pages

 

Medical Device ÜTS Registration Consultancy for Polyclinics

To open your ÜTS company registration as a polyclinic, set up your notification flow or carry out your sales center authorization certificate process, you can work with Medex. We review your current license and product list and tell you in writing which company type the registration will be opened under and which notifications are mandatory. Get a quote, call +90 505 580 46 22 or write to info@medexmedikal.com.Fiyat teklifi alın, +90 505 580 46 22 numarasını arayın veya info@medexmedikal.com adresine yazın.

Frequently Asked Questions

Under which company type is a polyclinic registered in ÜTS?

As a Health Service Provider. The registration of a private polyclinic is linked to the provincial health directorate's license record in ÇKYS; the responsible manager is pulled from ÇKYS and the company information from MERSİS.

Must a polyclinic obtain a sales center authorization certificate?

No. The authorization certificate is issued to those who want to become a sales center; a polyclinic uses devices and does not sell them. Selling devices to patients is possible only with a separate sales center authorization certificate.

What to do in ÜTS for an ultrasound and ECG device in a polyclinic?

Inventory notification. Under Article 8/1 of the Individual Movement Guide, a health service provider makes an inventory notification for fixed-asset devices subject to maintenance, repair and calibration; the serial number and acquisition date are mandatory.

What does a polyclinic that procures laboratory services from outside do in ÜTS?

The company providing the service opens a contract in ÜTS as a medical service provider; the polyclinic approves this contract. The stock of devices used in the service is not transferred to the polyclinic (Individual Movement Guide Article 32 and ANNEX-3).

What is done in ÜTS if the responsible manager changes?

The change is first processed in ÇKYS at the provincial health directorate; then "Update from ÇKYS" is performed in ÜTS on the My Company Information screen. Under Article 5/7 of the ÜTS Registration Guide, the responsible manager, title and address information updated in ÇKYS is updated automatically in ÜTS.

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.

bottom of page
WhatsApp Hemen Ara