top of page
< Back

Laboratory Diagnostic Center ÜTS Registration: IVD Kits, Analyzers and Service Provision

A laboratory diagnostic center that provides testing and imaging services is a health service provider that makes intensive use of in vitro diagnostic (IVD) kits and analyzers. Kit-based or result-based service models are tracked in ÜTS with a separate contract structure. This page explains, with quotations from the legislation, the laboratory's ÜTS registration, the notifications specific to IVD products and the service provision contract.

How a laboratory diagnostic center appears in the legislation

The Regulation on Sale, Advertising and Promotion of Medical Devices mentions the laboratory diagnostic center in the building restriction exception as follows:

"A sales center cannot be opened in a building that houses a healthcare institution or organization, including its garden and annexes, except for buildings that contain polyclinics and practices opened by physicians and dentists, laboratory diagnostic centers that provide only analysis and imaging services, pharmacies, opticianry establishments, hearing aid centers, custom-made prosthesis and orthosis centers and dental prosthesis laboratories."

Source: Medical Device Sales, Advertising and Promotion Regulation (RG 29001), Article 34, paragraph 1.

The expression 'laboratory diagnostic centers that provide only testing and imaging services' in the Regulation provision is the business type this page is about. The center is the party that uses the device, not the one that sells it; the Regulation defines this party as a health service provider (Article 4/k).

The Individual Movement Guide also mentions the laboratory field specifically for service procurement:

"Companies that provide services to health service providers in fields such as imaging, laboratory and dialysis through methods such as consumable/kit-based or result-based payment must have a company record in ÜTS as a Medical Service Provider."

Source: Guide on ÜTS Individual Movement Notifications of Medical Devices, Article 32, paragraph 1.

 

Under which company type is a laboratory diagnostic center registered in ÜTS

A laboratory diagnostic center licensed in its own name is registered as a 'Health Service Provider', like hospitals and polyclinics (ÜTS Registration Guide Article 29/1). The license of a private laboratory is kept in ÇKYS; the ÜTS responsible manager is pulled from there:

"First of all, the responsible manager of the company must also be defined as the responsible manager in the ÇKYS service. For this, company officials need to talk to the provincial health directorates and have their new manager added to the Agency."

Source: ÜTS User and Company Operations Help Guide, Question A6-1.

If the laboratory is a company, the registration is MERSİS-based; the signatory must be defined in MERSİS (ÜTS User and Company Operations Guide, Question A2-1). The users who can make all transactions on behalf of the company are the signatory, the institution official and the hospital manager (Question A1-6).

There is a second model: if the laboratory works as a company providing kit-based or result-based services to hospitals, a Medical Service Provider record is additionally required in ÜTS (Article 32/1). In this record type, the service areas are updated from the company information:

"After pressing the Management Operations button on the My Company Information screen (see Question B1-1), the company official presses the Update Service Area button that appears above it."

Source: ÜTS User and Company Operations Help Guide, Question B11-1.

 

Does a laboratory diagnostic center need a sales center authorization certificate

No. A laboratory uses kits and analyzers; it does not sell them, and under Article 5/1 the authorization certificate is for those who want to be authorized as a sales center. The laboratory's ÜTS record is nevertheless mandatory, because a sales center cannot sell devices other than Annex-3 devices to a place not registered in ÜTS:

"Except for the places specified in the guide published by the Agency, sales centers are prohibited from selling devices, other than the devices in Annex-3, to places not registered in the Agency's registration and information management system."

Source: Medical Device Sales, Advertising and Promotion Regulation (RG 29001), Article 26, paragraph 7.

IVD kits, specimen containers and analyzers are not in Annex-3. An unregistered laboratory cannot obtain these products from a sales center.

 

ÜTS notifications specific to IVD products

Because most of the products used in a laboratory are single-use consumables (test kits, reagents, specimen containers), the basic notification is the consumption notification:

"When products for which a usage notification will not be made by the health service provider are used, a “Consumption Notification” is made for these products."

Source: Guide on ÜTS Individual Movement Notifications of Medical Devices, Article 13, paragraph 1.

A usage notification, on the other hand, is for devices whose product record states that they are implantable, have a SUT match or can be used for a single patient (Article 12/2); IVD kits typically leave the system with a consumption notification. Analyzers, however, are fixed assets:

"Inventory notification is made in ÜTS by health service providers and medical service providers for fixed-asset medical devices within health service providers and medical service providers that are subject to maintenance, repair and calibration."

Source: Guide on ÜTS Individual Movement Notifications of Medical Devices, Article 8, paragraph 1.

The ÜTS Registration Guide also defines IVD devices used outside the laboratory separately; this distinction is made in the product record by the laboratory's supplier:

"Point-of-care test device: an in vitro diagnostic device that is not for personal testing and is used outside the laboratory environment, generally near or next to the patient, for a test to be performed by a healthcare professional,"

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 4, paragraph 1 subparagraph (r).

 

NotificationWhenBasisReceipt NotificationWhen kits, reagents, specimen containers and devices coming from a sales center are receivedIndividual Movement Guide Article 10/1Consumption NotificationWhen test kits, reagents and consumables are usedIndividual Movement Guide Article 13/1Inventory NotificationFor fixed-asset devices such as biochemistry and hematology analyzers and centrifugesIndividual Movement Guide Article 8/1Usage NotificationWhen devices that carry a usage notification requirement in the product record are used on a patientIndividual Movement Guide Article 12/1Service Procurement Contract ApprovalWhen kit-based or result-based services are procured from outsideIndividual Movement Guide ANNEX-3, step 6Write-off/Loss NotificationFor expired kits and reagentsIndividual Movement Guide Article 15/1

 

 

Kit-based service model: contract and consumption notification

A company that provides laboratory services to a hospital on a kit basis is a medical service provider. In ÜTS the process begins with the contract:

"First of all, a contract record must be made in ÜTS between the health service provider and the medical service provider. Subsequently, the consumables used during service provision under this contract must be removed from the system by the medical service provider company with a “Consumption Notification.”"

Source: Individual Movement Notifications Guide ANNEX-3 (Medical Service Providers), ANNEX-3, introduction.

The device stock does not pass to the hospital:

"The individual stocks in ÜTS of the medical devices used in transactions made by medical service provider companies will in no way be transferred to the health service provider, and the process will be managed through information on which device is used where and within which service."

Source: Individual Movement Notifications Guide ANNEX-3 (Medical Service Providers), ANNEX-3, introduction.

On the hospital side, the signatory, hospital manager or authorized user approves the contract (ANNEX-3, Note 1). After the contract end date, the medical service provider cannot make a consumption notification for that service (ANNEX-3, Note 4); therefore contract periods must be kept up to date in ÜTS. For the service provider side, see the medical service provider ÜTS registration page.tıbbi hizmet sağlayıcısı ÜTS kaydı sayfasına bakın.

 

Prerequisite documents and users

  • Laboratory license from the provincial health directorate and ÇKYS record (Question A6-1).
  • MERSİS number and the signatory defined in MERSİS (Question A2-1).
  • Responsible manager defined in ÇKYS (Situation 12).
  • Product number, serial number and acquisition date of analyzers (Article 8/2, ANNEX-1).
  • If a service is provided, a Medical Service Provider record and service area definition (Article 32/1, Question B11-1).

 

Common mistakes

  • Using test kits without a consumption notification; the kits pile up in the laboratory's stock in ÜTS (Article 13/1).
  • Not making an inventory notification for analyzers (Article 8/1).
  • Taking the analyzer of the company providing kit-based service into the laboratory's own inventory; stock is not transferred (ANNEX-3).
  • Not updating the end date of the service contract; consumption notification is blocked (ANNEX-3, Note 4).
  • Not accepting a sales center's supply notification with a receipt notification; the stock transfer does not take place (Article 9/2).
  • Having kits shipped to a laboratory branch that has no ÜTS record (Article 26/7).

 

Related pages

 

Medical Device ÜTS Registration Consultancy for Laboratory Diagnostic Centers

To open your ÜTS company registration as a laboratory diagnostic center, set up your notification flow or carry out your sales center authorization certificate process, you can work with Medex. We review your current license and product list and tell you in writing which company type the registration will be opened under and which notifications are mandatory. Get a quote, call +90 505 580 46 22 or write to info@medexmedikal.com.Fiyat teklifi alın, +90 505 580 46 22 numarasını arayın veya info@medexmedikal.com adresine yazın.

Frequently Asked Questions

Under which company type is a laboratory diagnostic center registered in ÜTS?

A laboratory licensed in its own name is registered as a Health Service Provider, linked to its ÇKYS license record. If it provides kit-based or result-based services to hospitals, a Medical Service Provider record is additionally required under Article 32/1 of the Individual Movement Guide.

Must a laboratory obtain a sales center authorization certificate?

No. A laboratory uses kits and analyzers; it does not sell them. An ÜTS record is, however, mandatory; under Article 26/7, sales centers cannot sell devices other than Annex-3 devices to places not registered in ÜTS, and IVD kits are not in Annex-3.

Which notification is made when test kits are used?

Consumption notification. Under Article 13/1 of the Individual Movement Guide, a consumption notification is made when products for which no usage notification will be made are used; the consumed quantity and consumption date are entered.

What is done in ÜTS for analyzers?

Inventory notification. Under Article 8/1, an inventory notification is made for fixed-asset devices subject to maintenance, repair and calibration; the serial number and acquisition date are mandatory, and it is not made with a lot number.

In whose stock does the analyzer of a hospital receiving kit-based service appear?

In the stock of the medical service provider providing the service. Under ANNEX-3, the individual stocks of the medical service provider are not transferred to the health service provider; fixed-asset devices are matched with the hospital by a service provision notification, and consumables are removed by the provider with a consumption notification.

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.

bottom of page
WhatsApp Hemen Ara