top of page
< Back

Custom-Made Prosthesis and Orthosis Center ÜTS Registration: ITC Application and Notifications

A custom-made prosthesis and orthosis center is a workplace that manufactures, sells and fits orthopedic prostheses and orthoses produced with patient-specific measurements and fittings. In ÜTS these centers have their own company type and their own device application type (custom-made medical device). This page explains the registration path, the authorization certificate status and the notifications, based on the text of the legislation.

How a custom-made prosthesis and orthosis center is defined in the ÜTS Registration Guide

"Custom-made prosthesis and orthosis center: Workplaces where custom-made orthopedic prostheses and orthoses are manufactured, sold, applied, maintained and repaired,"

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 4, paragraph 1 subparagraph (ş).

"Custom-made orthopedic prosthesis and orthosis manufactured and/or applied: Orthopedic prostheses and orthoses that are manufactured and/or must be applied through measurement and fitting for use in a specific patient,"

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 4, paragraph 1 subparagraph (s).

The Medical Device Sales, Advertising and Promotion Regulation, on the other hand, refers these centers to their own legislation (Regulation on Custom-Made Prosthesis and Orthosis Centers and Hearing Aid Centers, OG 28064) and keeps them in scope only with respect to ÜTS registration, distance sales, advertising and promotion:

"Public health institutions and organizations, opticianry establishments within the scope of the Regulation on Opticianry Establishments published in the Official Gazette dated 18/1/2014 and numbered 28886, custom-made prosthesis and orthosis centers and hearing aid centers within the scope of the Regulation on Custom-Made Prosthesis and Orthosis Centers and Hearing Aid Centers published in the Official Gazette dated 24/9/2011 and numbered 28064, and dental prosthesis laboratories within the scope of the Regulation on Dental Prosthesis Laboratories published in the Official Gazette dated 7/12/2005 and numbered 26016 are outside the scope of this Regulation. However, the trade, advertising, information, clinical support and promotion activities of medical devices placed on the market at or made available on the market through these places by means of distance communication, and the registration procedures for the registration and information management systems determined by the Agency, are within the scope of this Regulation."

Source: Medical Device Sales, Advertising and Promotion Regulation (RG 29001), Article 2, paragraph 2.

 

ÜTS company type: Custom-Made Orthosis-Prosthesis Application Center

The ÜTS Registration Guide lists these centers as a separate field in its definition of a company:

"Company: A company that sells and/or applies medical devices in fields such as medical device sales centers, manufacturers/importers/dealers/exporters, opticianry establishments, hearing aid application centers, custom-made orthosis-prosthesis application centers, pharmacies, pharmaceutical warehouses and similar,"

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 4, paragraph 1 subparagraph (o).

The main function of this company type in ÜTS is to be able to submit custom-made medical device (ITC) applications:

"In ÜTS, companies or organizations of the types “Healthcare Service Provider”, “Manufacturer/Importer/Dealer/Exporter” and “Custom-Made Orthosis-Prosthesis Application Center” can submit ITC applications under the MDR."

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 29, paragraph 1.

Who can submit the application for custom-made orthopedic prostheses and orthoses is also limited:

"only custom-made prosthesis and orthosis centers that manufacture the relevant custom-made orthopedic orthosis-prosthesis and whose activity area registered in ÜTS is “Custom-Made Orthosis-Prosthesis Application Center”, or"

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 29, paragraph 3 subparagraph (a).

The rest of the provision also extends the same authority to healthcare institutions that have orthopedic prosthesis and orthosis manufacturing services within their structure and whose activity area is Healthcare Service Provider. Therefore, the center enters the custom-made orthoses and prostheses it manufactures into the system only through its own ÜTS registration; it cannot grant a dealership to another company through this registration:

"institutions cannot grant dealerships for the custom-made orthopedic prostheses and orthoses they manufacture and/or apply."

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 29, paragraph 4.

 

Is a sales center authorization certificate required for a custom-made prosthesis and orthosis center?

Article 2, paragraph 2 of the Regulation leaves the centers outside the scope of the Regulation. Since the sales center authorization certificate is regulated in Articles 5 to 7 of this Regulation, no separate medical device sales center authorization certificate process is run for custom-made prosthesis and orthosis activity; the ÜTS company registration relies on the center being authorized under its own legislation, pursuant to Article 5/1 of the Guide.

The limit is this: if the center imports, or is the manufacturer of, devices such as mass-produced orthoses, walkers or wheelchairs, these products are not ITCs and a separate company registration of the Manufacturer/Importer/Dealer/Exporter type is required in ÜTS. A sales center license is mandatory for this registration type:

"In other words, companies that will register as a “Manufacturer/Importer/Dealer/Exporter” type in ÜTS must hold a medical device sales center license, and the ÇKYS number must be entered during company registration."

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 5, paragraph 5.

Since a medical device company can have only one activity area in ÜTS (ÜTS User and Company Transactions Guide, Case 15), a custom-made center and a manufacturer/importer registration are two separate company applications.

 

Mandatory Annex XIII statement in ITC registration

A statement based on MDR Annex XIII is prepared for each custom-made device. The Guide lists the information that must appear in the statement; one of them is the person who wrote the prescription:

"the name of the person who wrote the prescription (physician or dentist), authorized by virtue of their professional qualifications, and, if any, the name of the relevant healthcare institution,"

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 29, paragraph 5 subparagraph (d).

The retention period of the statement is also specified:

"The statement referred to in paragraph 5 of this article (Annex XIII ITC Statement) shall be kept for a period of at least 10 years after the device has been placed on the market. In the case of implantable devices, this period shall be at least 15 years."

Source: Guide on Medical Device Registration Processes in the Product Tracking System (TCKKD-KLVZ-03, V4.0), Article 29, paragraph 6.

On the ÜTS ITC registration screen, the physician who wrote the prescription is entered into the system with their ÇKYS diploma registration number; if there is an e-prescription, the patient, physician and healthcare facility details are retrieved automatically using the e-prescription number. The physician details entered must be exactly the same as the information on the prescription.

 

Mandatory ÜTS notifications of a custom-made prosthesis and orthosis center

 

NotificationWhenBasisCustom-Made Medical Device ApplicationFor each orthosis and prosthesis made specifically for a patient, before the device is given to the patientÜTS Registration Guide Article 29/1 and 29/3-aReceipt NotificationWhen a ready-made (mass-produced) device is received from the supplierIndividual Movement Guide Article 10/1Delivery-to-Consumer NotificationWhen a ready-made device is sold to the consumerIndividual Movement Guide Article 14/1Transfer NotificationWhen the device is given to another ÜTS-registered company or institutionIndividual Movement Guide Article 9/1Disposal/Loss NotificationFor individual products that are lost or have completed their economic lifeIndividual Movement Guide Article 15/1

 

"A transfer notification is made when individual products owned by an institution/company/hospital are to be given to another institution/company/hospital."

Source: Guide on ÜTS Individual Movement Notifications of Medical Devices, Article 9, paragraph 1.

"A disposal/loss notification is made by the institution/company/hospital for individual products that have completed their economic life or have been lost."

Source: Guide on ÜTS Individual Movement Notifications of Medical Devices, Article 15, paragraph 1.

 

Online sales and advertising

Online sales addressed to consumers of devices sold, adapted or applied at the center are prohibited (Article 26/5-a). The TİTCK guide introduces a narrow exception to this prohibition:

"Online sales by custom-made prosthesis and orthosis centers of the medical devices on the Annex-9 list of the Regulation on Custom-Made Prosthesis and Orthosis Centers and Hearing Aid Centers may be made provided that they comply with the provisions of the Regulation."

Source: Guide on the Implementation of the Medical Device Sales, Advertising and Promotion Regulation (TCS-KLVZ-08, Version 4), Article 16, paragraph 12.

In terms of advertising as well, the same group of devices cannot be advertised to consumers:

"Only devices sold, adapted or applied at hearing aid centers, custom-made prosthesis and orthosis centers, opticianry establishments or dental prosthesis laboratories,"

Source: Medical Device Sales, Advertising and Promotion Regulation (OG 29001), Article 15, paragraph 1, subparagraph (a).

"cannot be advertised to consumers."

Source: Medical Device Sales, Advertising and Promotion Regulation (OG 29001), Article 15, paragraph 1.

 

Prerequisite documents

  • The license under the Regulation on Custom-Made Prosthesis and Orthosis Centers and Hearing Aid Centers (ÜTS Registration Guide Article 5/1).
  • MERSİS number or VEDOP tax identification number (ÜTS Registration Guide Article 5/2).
  • A written prescription and the Annex XIII ITC statement for each ITC (ÜTS Registration Guide Article 29/5).
  • The prescribing physician's ÇKYS diploma registration number or the e-prescription number for the ITC registration screen.

 

Common mistakes

  • Registering a mass-produced orthosis as an ITC. The ITC definition is limited to a device made specifically according to a written prescription for the individual condition of a specific patient (ÜTS Registration Guide Article 4/t).
  • Trying to grant a dealership to another company for a custom-made orthosis (Article 29/4).
  • Not keeping the ITC statement; the period is at least 10 years, and at least 15 years for implantable devices (Article 29/6).
  • The physician information on the prescription differing from the physician information entered in ÜTS.
  • Trying to enter imported ready-made devices into the system under the custom-made center registration; an importer registration is a separate company type and requires a sales center license (Article 5/5).

 

Related pages

 

Medical Device ÜTS Registration Consultancy for Custom-Made Prosthesis and Orthosis Centers

To open your ÜTS company registration as a custom-made prosthesis and orthosis center, set up your notification flow or carry out your sales center authorization certificate process, you can work with Medex. We review your current license and product list and tell you in writing which company type the registration will be opened under and which notifications are mandatory. Get a quote, call +90 505 580 46 22 or write to info@medexmedikal.com.Fiyat teklifi alın, +90 505 580 46 22 numarasını arayın veya info@medexmedikal.com adresine yazın.

Frequently Asked Questions

Which company type does a custom-made prosthesis and orthosis center register as in ÜTS?

The ÜTS Registration Guide defines the activity area 'Custom-Made Orthosis-Prosthesis Application Center' for these centers (Article 4/o and Article 29/1). Applications for custom-made orthopedic orthoses and prostheses can only be made by centers registered under this activity area or by healthcare service providers that have manufacturing services within their structure.

Does a custom-made prosthesis and orthosis center have to obtain a sales center authorization certificate?

Kendi faaliyeti için hayır; Yönetmeliğin 2/2 maddesi bu merkezleri kapsam dışında tutar. Hazır cihaz ithal eden veya üreten merkez ise Üretici/İthalatçı/Bayi/İhracatçı türünde ayrı bir ÜTS kaydı açmak zorundadır ve bu kayıt için satış merkezi ruhsatı ile ÇKYS numarası şarttır.

Is a separate ÜTS application required for the orthosis made for each patient?

Yes. The definition of a custom-made medical device refers to a device made specifically for a particular patient according to a prescription; for each device, an Annex XIII statement containing the details of the prescribing physician and the patient is prepared and an ITC application is made in ÜTS.

Can a dealership be granted for a custom-made orthosis?

No. Under Article 29/4 of the ÜTS Registration Guide, centers that manufacture custom-made orthopedic prostheses and orthoses cannot grant dealerships for these products. Dealerships can only be granted by manufacturer or importer companies, and only for ITCs other than custom-made orthopedic orthoses-prostheses.

Can a custom-made prosthesis and orthosis center sell online?

Under Article 26/5, online sales addressed to consumers of devices sold, adapted or applied at the center are prohibited. Article 16/12 of TCS-KLVZ-08 allows online sales only for devices on the Annex-9 list of its own Regulation, provided they comply with the Regulation's provisions.

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.

bottom of page
WhatsApp Hemen Ara