Documents Required for ÜTS Registration of Products Under the IVDR

12 hours ago
5 min read
IVDR cihazların ÜTS kaydı için belgeler: risk sınıfı, uygunluk yolu ve ÜTS belge kuralları

SUMMARY

In vitro diagnostic medical devices are classified as Class A, B, C or D under the In Vitro Diagnostic Medical Device Regulation. The class determines the conformity assessment route; which documents are linked to the device in ÜTS is also regulated by separate document business rules according to the risk class.

In this guide we explain the IVDR risk classes, the conformity assessment route by class, the risk class to be selected in ÜTS and the documents to be uploaded to ÜTS, based on the provisions of the Regulation and the ÜTS Registration Guideline.

IVDR kapsamındaki cihazlarınızın ÜTS belge ve ürün kaydı için: Tıbbi Cihaz ÜTS Kayıt Danışmanlığı

Contents

1. IVDR and the In Vitro Diagnostic Medical Device Regulation

Regulation (EU) 2017/746 on in vitro diagnostic medical devices (IVDR) is applied in Türkiye through the In Vitro Diagnostic Medical Device Regulation (İn Vitro Tanı Amaçlı Tıbbi Cihaz Yönetmeliği) published in the Official Gazette No. 31499 (repeated) dated 2/6/2021. The documents required for ÜTS registration are determined under the provisions of this Regulation and the TİTCK Guideline on the Registration Processes of Medical Devices to the Product Tracking System (TCKKD-KLVZ-03).

2. IVDR Risk Classes

Article 49 of the Regulation sets the basis of classification:

“Devices are classified as Class A, B, C or D, taking into account the risks inherent in their intended purpose and design. Classification is carried out in accordance with Annex VIII.”

For the details of classification, see our How are IVD devices classified? page.

3. Conformity Assessment Route by Class

IVDR risk sınıfına göre uygunluk değerlendirme yolu: Sınıf A, B, C ve D
IVDR risk sınıfına göre uygunluk değerlendirme yolu. Dayanak: İn Vitro Tanı Amaçlı Tıbbi Cihaz Yönetmeliği Madde 50.

Class A (Article 50, tenth paragraph):

“Manufacturers of Class A devices, other than devices for performance study, shall declare the conformity of their products by issuing the EU declaration of conformity referred to in Article 18 after drawing up the technical documentation set out in Annexes II and III. However, if these devices are placed on the market in a sterile condition, the manufacturer shall apply the procedures set out in Annex IX or Annex XI. The involvement of the notified body shall be limited to the aspects relating to establishing, securing and maintaining sterile conditions.”

Class B (Article 50, ninth paragraph):

“Manufacturers of Class B devices, other than devices for performance study, shall be subject to a conformity assessment as specified in Chapters I and III of Annex IX and to an assessment of the technical documentation, as specified in Section 4 of the same Annex, of at least one representative device for each category of devices.”

Class C (Article 50, seventh paragraph, point (a)):

“Manufacturers of Class C devices, other than devices for performance study, shall be subject to a conformity assessment as specified in Chapters I and III of Annex IX, including an assessment of the technical documentation, as specified in Section 4 of the same Annex, of at least one representative device for each generic device group.”

Class D (Article 50, third paragraph):

“Manufacturers of Class D devices, other than devices for performance study, shall be subject to a conformity assessment as specified in Chapter I, Chapter II excluding Section 5, and Chapter III of Annex IX.”

Additional procedures are provided in the same article for self-testing, near-patient testing and companion diagnostic devices.

4. IVDR Risk Class Selection in ÜTS

In a product registration under the IVDR, the risk class is selected under the "Sınıflandırma Bilgileri" (Classification Information) heading. ÜTS Registration Guideline Article 30:

“According to the risk classes that can be selected under the IVDR, the appropriate one is selected from the options "Sınıf A Steril" (Class A Sterile), "Sınıf A", "Sınıf B", "Sınıf C", "Sınıf D", "Kişisel Test Cihazı (Sınıf B)" (Self-Testing Device, Class B), "Kişisel Test Cihazı (Sınıf C)", "Kişisel Test Cihazı (Sınıf D)", "Hastabaşı Test Cihazı (Sınıf B)" (Near-Patient Testing Device, Class B), "Hastabaşı Test Cihazı (Sınıf C)", "Hastabaşı Test Cihazı (Sınıf D)", "Destek Tanı Cihazı (Sınıf C)" (Companion Diagnostic Device, Class C) and "Destek Tanı Cihazı (Sınıf D)" in the relevant field.”

5. Documents to Be Uploaded to ÜTS

The documents are linked to the device by document business rules according to the type and risk class of the device. Guideline Article 67:

  • “For a device registration notification under the IVDR, pursuant to item (a) of the fifth paragraph of Article 30 of this Guideline, according to the type and risk class of the device concerned, the appropriate one or ones of the documents that are in the "Kayıtlı" (Registered) status in ÜTS as a result of an application already made under the relevant provisions specified in Article 39 of this Guideline and that are mentioned in Articles 7, 11, 17, 20, 22, 23 and 24 of this Guideline must be linked to the device in question.”

  • “For devices to be registered in ÜTS under the IVDR as "Sınıf A" or "Sınıf A Steril", the appropriate one of the ÜTS document business rules shown in Annex-94 is applied.”

  • “For devices to be registered in ÜTS under the IVDR as "Sınıf B" or "Sınıf C", the appropriate one of the ÜTS document business rules shown in Annex-95 is applied.”

  • “For devices to be registered in ÜTS under the IVDR as "Sınıf D", the appropriate one of the ÜTS document business rules shown in Annex-96 is applied.”

Notified body information in the EU declaration of conformity (Guideline Article 11):

“For EU declarations of conformity other than those covering only Sınıf-I Diğer or Class A devices; the name and identification number of the notified body, a description of the conformity assessment procedure carried out, and the identification of the EU certificate or certificates issued (certificate number or numbers),”

Instructions for use (Guideline Article 17):

  • “For Class B, Class C and Class D devices certified under the IVDR, and Self-Testing Devices (Class B/C/D), Near-Patient Testing Devices (Class B/C/D) and Companion Diagnostic Devices (Class C/D), uploading the instructions for use issued by the manufacturer … is mandatory.”

  • “For device groups in other risk groups (for Sınıf-I Diğer, Sınıf-Im, Sınıf-Is, Sınıf-Ir, Class A, Class A Sterile and IVD Other devices), uploading instructions for use is optional.”

For the document registration steps, see our ÜTS document registration guide, and for product registration, see our ÜTS IVD product registration guide.

6. IVDR Transition Dates

The transition dates by class are listed separately in our legislation calendar:

7. Related Guides

IVDR geçişi, uygunluk beyanı ve ÜTS kaydınız için: Tıbbi Cihaz ÜTS Kayıt Danışmanlığı

Source: In Vitro Diagnostic Medical Device Regulation (Official Gazette 02.06.2021, No. 31499 repeated), Articles 49 and 50; TİTCK, Guideline on the Registration Processes of Medical Devices to the Product Tracking System (Tıbbi Cihazların Ürün Takip Sistemine Kayıt Süreçlerine İlişkin Kılavuz) (TCKKD-KLVZ-03), Articles 11, 17, 30 and 67.

 
 

Medical Device ÜTS Registration Consultancy

Request an ÜTS registration consultancy quote

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.