What Is ÜTS? Company Registration, Medical Device Registration, Document Registration and Consultancy Guide (2026 Update)

12 hours ago
21 min read
ÜTS nedir: firma, belge ve ürün kaydı rehberi

SUMMARY

ÜTS (Product Tracking System) is the official registration and tracking system managed by the Turkish Medicines and Medical Devices Agency (TİTCK) of the Republic of Türkiye Ministry of Health. In Türkiye, it tracks medical devices, cosmetics and Type-1 and Type-19 biocidal products that come into contact with the human body individually, from the manufacturing or import stage to the end user. ÜTS registration is a legal requirement for placing medical devices on the market, importing, manufacturing or selling them, or taking part in tenders in Türkiye. In this guide we cover ÜTS company registration, document registration, medical device product registration, the relevant regulations, device classes, MDR, IVDR, EUDAMED, the transition from MDD/IVDD to MDR/IVDR, CE certificate extension and custom-made medical devices in detail, relying only on official sources. As Medex Kurumsal Danışmanlık, with more than ten years of experience in the sector, we provide end-to-end support to companies at every stage of ÜTS processes.

For your ÜTS company, document and product registration: Medical Device ÜTS Registration Consultancy

Contents

  • 1. What Is ÜTS? (Definition of the Product Tracking System)

  • 2. How Is ÜTS Company Registration Done? (Step-by-Step Official Process)

  • 3. ÜTS Document Registration: CE Certificate and EU Declaration of Conformity

  • 4. ÜTS Medical Device (Product) Registration

  • 5. Medical Device Risk Classes (MDR Annex VIII / IVDR)

  • 6. Medical Device Import and ÜTS

  • 7. Domestic Medical Device Manufacturing and ÜTS

  • 8. Regulations: Full List of Medical Device Legislation

  • 9. MDR (EU 2017/745): Medical Devices Regulation

  • 10. IVDR (EU 2017/746): In Vitro Diagnostic Medical Devices Regulation

  • 11. Transition from MDD and IVDD to MDR / IVDR and CE Certificate Extension

  • 12. EUDAMED: European Database on Medical Devices

  • 13. Custom-Made Medical Devices and ÜTS

  • 14. Other Important Processes Under ÜTS

  • 15. Most Common Mistakes in ÜTS Processes

  • 16. ÜTS Processes with Medex Kurumsal Danışmanlık

  • 17. Frequently Asked Questions About ÜTS (FAQ)

  • 18. Conclusion

1. What Is ÜTS? (Definition of the Product Tracking System)

The Product Tracking System (ÜTS) is an e-Government application developed jointly by the Turkish Medicines and Medical Devices Agency (TİTCK) of the Republic of Türkiye Ministry of Health and the TÜBİTAK BİLGEM Software Technologies Research Institute (YTE), and it went live on 12.06.2017. Following the official approval dated 02.06.2017 and numbered E.1967, ÜTS replaced the Turkish Medicines and Medical Devices National Data Bank (TİTUBB) system.

ÜTS sayesinde:

  • Every medical device produced or imported in Türkiye is recorded individually.

  • The device is tracked across the whole supply chain, starting from the manufacturer / importer through the distributor, sales center, hospital, pharmacy and the end user.

  • Counterfeit, smuggled, black-market and unapproved products are prevented from being on the market.

  • Patient safety and public health are protected.

  • Recall operations are carried out quickly and effectively.

  • TİTCK inspections can be carried out electronically.

ÜTS works integrated with many external systems such as the Social Security Institution (SGK / MEDULA), the Revenue Administration (VEDOP), the Central Registration System (MERSİS), the Core Resource Management System (ÇKYS) and the Risk-Based Control System in Foreign Trade (TAREKS).

Legal Basis of ÜTS

The legal basis of ÜTS is Article 34 ("National product tracking system") of the Tıbbi Cihaz Yönetmeliği (Medical Device Regulation), published in Official Gazette No. 31499 (Repeated) dated 02.06.2021, together with the relevant provisions of the İn Vitro Tanı Amaçlı Tıbbi Cihaz Yönetmeliği (In Vitro Diagnostic Medical Device Regulation). Under that article, economic operators established in Türkiye (manufacturers, authorised representatives, importers, system/procedure pack producers), notified bodies, healthcare institutions and healthcare professionals must fulfil their ÜTS obligations, without prejudice to their EUDAMED obligations.

Core legal texts of the legislation:

  • Law No. 7223 on Product Safety and Technical Regulations, dated 5/3/2020

  • Tıbbi Cihaz Yönetmeliği (Medical Device Regulation) (RG: 02.06.2021 / 31499 Repeated)

  • İn Vitro Tanı Amaçlı Tıbbi Cihaz Yönetmeliği (In Vitro Diagnostic Medical Device Regulation) (RG: 02.06.2021 / 31499 Repeated)

  • Tıbbi Cihaz Satış, Reklam ve Tanıtım Yönetmeliği (Medical Device Sales, Advertising and Promotion Regulation) (15.05.2014 / 28998, last amended RG: 26.05.2023 / 32202)

  • Tıbbi Cihazların Test, Kontrol ve Kalibrasyonu Hakkında Yönetmelik (Regulation on Testing, Control and Calibration of Medical Devices)

  • EU Medical Devices Regulation No. 2017/745 (MDR)

  • EU In Vitro Diagnostic Medical Devices Regulation No. 2017/746 (IVDR)

Products Within the Scope of ÜTS

ÜTS covers the following product groups:

  • Medical devices: All devices within the scope of the Medical Device Regulation, their accessories and the non-medical-purpose products listed in Annex XVI of the Regulation.

  • In vitro diagnostic medical devices (IVD): Products used for examining specimens outside the human body, such as reagents, calibrators, control materials, test kits, rapid diagnostic tests, microbiology culture media and PCR devices.

  • Cosmetic products: All cosmetics within the scope of Cosmetics Law No. 5324.

  • Biocidal products: Authorised biocidal products of Product Type-1 (human hygiene) and Product Type-19 (repellents / attractants for humans or animals) that come into contact with the human body.

2. How Is ÜTS Company Registration Done? (Step-by-Step Official Process)

ÜTS company registration is the first legal step for every company that will operate as a medical device manufacturer, importer, authorised representative, distributor or sales center. Until ÜTS company registration is completed, medical device registration, document registration, tenders, imports or SGK reimbursement transactions cannot be carried out.

Prerequisites for ÜTS Company Registration

For an ÜTS company registration application to be accepted, the following prerequisites must be met in full:

  1. The company's MERSİS (Central Registration System) record must be up to date and active.

  2. Tax office (VEDOP) records must be consistent with ÜTS.

  3. The signatory holding an e-signature must be authorised on behalf of the company, and the signature circular must be up to date.

  4. A Medical Device Sales Center Authorization Certificate appropriate to the company's field of activity must have been obtained.

  5. An ÇKYS number must be held: under the TİTCK announcement, the ÜTS records of companies without an ÇKYS number are being made passive.

  6. A Person Responsible for Regulatory Compliance (PRRC) must be appointed (mandatory for manufacturers and authorised representatives).

  7. Personnel holding the Medical Device Registration Staff (TCKE) qualification certificate must be employed.

Medical Device Sales Center Authorization Certificate (Provincial Health Directorate)

Under the Tıbbi Cihaz Satış, Reklam ve Tanıtım Yönetmeliği (RG: 15.05.2014 / 28998), all companies engaged in manufacturing, importing, distributing, selling or applying medical devices must obtain a Medical Device Sales Center Authorization Certificate from the Provincial Health Directorate they are affiliated with. TİTCK does not accept a company registration application until this certificate is obtained.

The following personnel are mandatory at the sales center for the authorization certificate application:

  • Responsible Manager (SM): A person with at least an associate degree who has obtained a qualification certificate through training and an exam.

  • Sales and Promotion Staff (STE): A person with at least an associate degree for whom a work permit and identity card have been issued.

  • Clinical Support Staff (KDE): A graduate of the health-field departments specified in the Regulation, for whom a work permit has been issued (where required by the activity).

Under the Regulation, the responsible manager and the sales and promotion staff cannot be the same person, and every sales center must have at least one responsible manager and at least one sales and promotion staff member.

Medical Device Registration Staff (TCKE) Requirement

Under the amendment introduced by the Regulation Amending the Medical Device Sales, Advertising and Promotion Regulation, published in Official Gazette No. 32202 dated 26.05.2023, from 01.01.2025 the personnel who register medical devices in ÜTS must hold the Medical Device Registration Staff (TCKE) qualification certificate. Registration applications made by personnel without a TCKE certificate are not accepted by TİTCK.

TCKE training and exams are carried out through the Medical Device Training System (TCESİS); a qualification certificate is issued to candidates with a pass mark of 70 or above.

Mevzuat Uyum Sorumlusu (PRRC)

Under the Medical Device Regulation, manufacturers and authorised representatives must have at least one "Person Responsible for Regulatory Compliance" (PRRC) with the required expertise in the field of medical devices within their organisation. EUDAMED actor registration cannot be completed without the PRRC appointment in the ÜTS system.

ÜTS Company Registration Step by Step

  1. Preparation: MERSİS, ÇKYS, e-signature, signature circular, activity certificate, tax plate and the Provincial Health Directorate Authorization Certificate are obtained.

  2. TCESİS / Qualification Certificate: The training and exam process is completed through TCESİS for the responsible manager, the sales and promotion staff and the medical device registration staff.

  3. Provincial Health Directorate Application: The Medical Device Sales Center Authorization Certificate is obtained.

  4. ÜTS Application: The person logs in to the ÜTS portal via e-Government with an e-signature, and the signatory is defined.

  5. Company Definition: Company title, MERSİS details, tax office, address, e-mail, telephone and fax information are transferred to the system. The system pulls company information automatically from MERSİS.

  6. Activity Type Selection: Roles such as manufacturer, importer, authorised representative, system and procedure pack producer and distributor are selected. Separate registrations may be required for more than one role.

  7. User Authorization: PRRC, TCKE and other users are defined.

  8. Approval: The application is reviewed by TİTCK; if nothing is missing, the company registration is activated.

“Important: The activities of companies whose operations have been suspended or made passive by TİTCK can only be restarted by TİTCK; the company cannot reactivate itself.”

3. ÜTS Document Registration: CE Certificate and EU Declaration of Conformity

After ÜTS company registration is completed, the second stage is registering the documents of the medical devices to be placed on the market in the system. Product (device) registration cannot be done without document registration.

Main Documents Registered in ÜTS

  • EC / CE Certificate: A document issued by a notified body proving that the device complies with the requirements of EU 2017/745 (MDR) or EU 2017/746 (IVDR) or, during the transition period, 93/42/EEC (MDD), 90/385/EEC (AIMDD) and 98/79/EC (IVDD).

  • EU Declaration of Conformity (DoC): A document in which the manufacturer, under its own responsibility, declares that the device complies with the relevant EU regulation / directive.

  • Authorised Representative Agreement: Manufacturers not established in Türkiye or EU member states must appoint an authorised representative in Türkiye.

  • Importer Agreement / Power of Attorney: A document showing that the importer has been authorised by the manufacturer or the authorised representative.

  • Free Sale Certificate (FSC): Required for exports abroad; a document obtained from the official authority in the manufacturer's country.

  • ISO 13485 Certificate: The quality management system certificate for medical devices.

  • Clinical Evaluation Report / Performance Evaluation Report: The clinical data required by MDR / IVDR.

  • Technical File Summary (STED / Technical Documentation)

EU Declaration of Conformity for Class I Devices

For Class I medical devices (non-sterile, without a measuring function, and not reusable surgical instruments), the manufacturer can prepare an EU Declaration of Conformity under its own responsibility and register it in ÜTS; involvement of a notified body is not mandatory. However, if a Class I device falls into the sterile (Is), measuring function (Im) or reusable surgical instrument (Ir) subcategories, notified body approval is required.

EC/CE Certificate for Class IIa, IIb, III and IVD

For Class IIa, IIb and III medical devices and Class B, C and D in vitro diagnostic devices, a valid EC/CE certificate issued by a notified body must be registered in ÜTS. If the certificate is invalid, suspended or withdrawn, the device cannot be registered; existing records are made passive.

4. ÜTS Medical Device (Product) Registration

After document registration is completed, the third and final stage is medical device product registration. Each product is registered separately, and each product must have a unique GS1 barcode in GTIN-14 format.

Mandatory Information in Medical Device Registration

  • Product name, trade name, model / catalog number

  • Basic UDI-DI and UDI-DI (Unique Device Identifier: EU 2017/745 Article 27)

  • Risk class (Class I, Is, Im, Ir, IIa, IIb, III or Class A, B, C, D)

  • GMDN (Global Medical Device Nomenclature) kodu

  • EMDN (European Medical Device Nomenclature) code: the new nomenclature system introduced under MDR Article 26 and IVDR Article 23

  • Manufacturer, authorised representative (if any) and importer information

  • Related EC/CE certificate or EU Declaration of Conformity information

  • Label and instructions for use (including Turkish)

  • Packaging / pack information, shelf life, expiry date

  • Sterile / measuring function / single-use characteristics

UDI (Unique Device Identification) Sistemi

UDI is the mandatory coding system introduced by MDR for the traceability of medical devices. It consists of two components:

  • UDI-DI (Device Identifier): The fixed code that uniquely identifies the device model.

  • UDI-PI (Production Identifier): The variable part containing production data such as lot number, serial number, manufacturing date and expiry date.

In addition, the Basic UDI-DI is the primary identifier of a family of devices with the same design and intended purpose, and it must appear in the EU Declaration of Conformity.

5. Medical Device Risk Classes (MDR Annex VIII / IVDR)

Medical devices are divided into the following classes under the 22 classification rules in MDR Annex VIII:

Medical Device Regulation (MDR) Classes

































Class

Risk Level

Examples

Class A

Low individual and public health risk

General laboratory reagents, specimen containers, culture media

Class B

Moderate individual risk / Low public health risk

Pregnancy tests, urine test strips, cholesterol tests

Class C

High individual risk / Moderate public health risk

Blood glucose measurement, HbA1c, coagulation tests, some immunoassay systems

Class D

High individual and public health risk

HIV, Hepatitis B/C, blood group determination, transfusion safety tests

“Notified body involvement is mandatory for Class B, C and D. Class D products may also be subject to verification by the EU Reference Laboratory (EURL).”

6. Medical Device Import and ÜTS

The import of medical devices into Türkiye is carried out in compliance with the legislation of both the TİTCK of the Republic of Türkiye Ministry of Health and the Republic of Türkiye Ministry of Trade. It is not legally possible to clear a medical device from customs without ÜTS registration.

TAREKS Sistemi

The Risk-Based Control System in Foreign Trade (TAREKS) of the Ministry of Trade automatically checks medical devices in customs procedures. Products without ÜTS registration are rejected directly by TAREKS. The procedures and principles of import inspection are set by the Ministry of Trade's "Tıbbi Cihazların İthalat Denetimi Tebliği" (Communiqué on Import Inspection of Medical Devices), which is updated every year within the product safety and inspection communiqués; for example, Communiqué No. 2026/16 was published in Official Gazette No. 33124 dated 31.12.2025.

Import Process Step by Step

  1. An authorisation agreement is drawn up between the manufacturer and the importer.

  2. The importing company completes its ÜTS company registration.

  3. The CE certificate and the EU Declaration of Conformity issued by the manufacturer are uploaded to ÜTS.

  4. The product registration of the device (UDI-DI, GMDN, EMDN, label, etc.) is completed.

  5. A TİTCK expert review is carried out for Class IIb and III devices.

  6. Customs procedures are carried out through TAREKS.

  7. Cihazlar piyasaya arz edilir.


For details of import and ÜTS processes, see our article:

7. Domestic Medical Device Manufacturing and ÜTS

For domestic manufacturers, ÜTS registration is made in the manufacturer role. The manufacturing company is obliged to upload the production facility address, quality management system certificates (ISO 13485, etc.), the GMP certificate (where required), clinical evaluation reports and the technical file to the system. For Class IIa and above, product registration cannot be made without an EC certificate issued by a notified body.

The policies of the Ministry of Health and the Ministry of Industry and Technology that support domestic production (the Domestic Medical Device List, SGK SUT positive list advantages, price advantages for domestic manufacturers in public tenders) apply to devices whose ÜTS registration has been completed.

8. Regulations: Full List of Medical Device Legislation

Tıbbi Cihaz Yönetmeliği (Medical Device Regulation, MDR-Aligned)

  • Official Gazette: 02.06.2021 / 31499 Repeated

  • EU Equivalent: EU Medical Devices Regulation No. 2017/745 (MDR)

  • Repealed: The Tıbbi Cihaz Yönetmeliği dated 07.06.2011 and numbered 27957 (MDD: 93/42/EEC) and the Vücuda Yerleştirilebilir Aktif Tıbbi Cihazlar Yönetmeliği (AIMDD: 90/385/EEC).

  • Scope: All medical devices other than in vitro diagnostic devices, their accessories and the non-medical-purpose products listed in Annex XVI (cosmetic contact lenses, liposuction devices, fillers, etc.).

İn Vitro Tanı Amaçlı Tıbbi Cihaz Yönetmeliği (In Vitro Diagnostic Medical Device Regulation, IVDR-Aligned)

  • Official Gazette: 02.06.2021 / 31499 Repeated

  • EU Equivalent: EU IVDR No. 2017/746

  • Repealed: The Vücut Dışında Kullanılan (İn Vitro) Tıbbi Tanı Cihazları Yönetmeliği dated 09.01.2007 and numbered 26398 (IVDD: 98/79/EC).

Tıbbi Cihaz Satış, Reklam ve Tanıtım Yönetmeliği (Medical Device Sales, Advertising and Promotion Regulation)

  • Official Gazette: 15.05.2014 / 28998 (last amendment RG: 26.05.2023 / 32202)

  • It regulates the requirements for the sales center authorization certificate, responsible manager, sales and promotion staff, clinical support staff and medical device registration staff.

Tıbbi Cihazların Test, Kontrol ve Kalibrasyonu Hakkında Yönetmelik (Regulation on Testing, Control and Calibration of Medical Devices)

  • It sets the procedures and principles for testing, control and calibration services to be provided by organisations to which TİTCK has issued an authorization certificate.

Ismarlama Protez ve Ortez Merkezleri ile İşitme Cihazı Merkezleri Hakkında Yönetmelik (Regulation on Custom-Made Prosthesis and Orthosis Centers and Hearing Aid Centers)

  • Resmî Gazete: 24.09.2011 / 28064

Diş Protez Laboratuvarları Yönetmeliği (Dental Prosthesis Laboratories Regulation)

  • Resmî Gazete: 07.12.2005 / 26016

9. MDR (EU 2017/745): Medical Devices Regulation

The Medical Device Regulation (MDR) is the current legislation governing the safety, quality and performance of medical devices in the European Union. It entered into force on 26 May 2021 and replaced the 93/42/EEC (MDD) and 90/385/EEC (AIMDD) Directives. Türkiye transposed it into national law by publishing the Tıbbi Cihaz Yönetmeliği, fully aligned with the MDR, in Official Gazette No. 31499 (Repeated) dated 02.06.2021.

Main Innovations Introduced by the MDR

  • Stricter clinical data requirements: The clinical evaluation process has been strengthened (MDR Article 61).

  • UDI (Unique Device Identifier) System: Every device can now be tracked uniquely.

  • EUDAMED database: Central transparency has been provided across the EU.

  • Annex XVI products: Certain aesthetic-purpose products (coloured contact lenses, lipolysis devices, fillers, etc.) have been brought into medical device legislation.

  • Up-classification of some devices: Reusable surgical instruments have moved from Class I to Class Ir, some IIa devices to IIb, and some IIb implants to III.

  • Person Responsible for Regulatory Compliance (PRRC): A mandatory person within manufacturers and authorised representatives.

  • Strengthening of notified bodies: New designation criteria and stricter oversight.

  • Post-market surveillance (PMS) and vigilance: More comprehensive reporting obligations (PSUR, PMCF).

10. IVDR (EU 2017/746): In Vitro Diagnostic Medical Devices Regulation

The In Vitro Diagnostic Regulation (IVDR) entered into force on 26 May 2022 and replaced the IVDD No. 98/79/EC. In Türkiye it was transposed into national law as the İn Vitro Tanı Amaçlı Tıbbi Cihaz Yönetmeliği.

Main Innovations Introduced by the IVDR

  • Reclassification: A risk-based A-B-C-D classification has replaced the "list-based" system of the IVDD.

  • Wider notified body scope: Under the IVDD, about 20% of devices were subject to notified body oversight, while with the IVDR this share has risen to 80%.

  • EU Reference Laboratories (EURL): Verification authority for Class D devices.

  • Performance evaluation report: The clinical evidence requirement has been strengthened.

  • In-house device exemption: An exemption under certain conditions for devices that healthcare institutions make for their own use.

11. Transition from MDD and IVDD to MDR / IVDR and CE Certificate Extension

Because of capacity problems the medical device sector faced during the transition to MDR and IVDR (insufficient notified bodies, EUDAMED delays, device supply risk), the MDR transition period was extended by Regulation (EU) 2023/607, published in the Official Journal of the EU on 20.03.2023, and the IVDR transition period was rearranged by Regulation (EU) 2024/1860.

MDR Transition Period Extension: EU 2023/607 (Class-Based Dates)

Under Regulation (EU) 2023/607, devices covered by a valid EC certificate or declaration of conformity issued under 90/385/EEC or 93/42/EEC may continue to be placed on the market or put into service until the following dates, provided they meet certain conditions:

  • 26 May 2026: Class III implantable custom-made medical devices.

  • 31 December 2027: Class III devices and Class IIb implantable devices, excluding sutures, staples, dental fillings, dental braces, tooth crowns, screws, wedges, plates, wires, pins, clips and connectors.

  • 31 December 2028: Class IIb devices other than those covered above, Class IIa devices, Class I devices placed on the market in sterile condition (Is) or with a measuring function (Im), reusable surgical instruments (Ir) that require a notified body under the MDR, and devices that were Class I under the MDD but have been moved to a higher class under the MDR.

Conditions for the Transition Period Extension

To benefit from the transition period extension introduced by (EU) 2023/607, manufacturers must meet the following conditions:

  1. The device must have been brought into line with the MDR quality management system (Article 10(9)) by 26.05.2024.

  2. A formal application for MDR certification must have been submitted to a notified body by 26.05.2024.

  3. A written agreement must have been signed with the relevant notified body by 26.09.2024.

  4. The device must continue to comply with the MDD/AIMDD, and no "significant change" must have been made to its design and intended purpose.

  5. The device must not pose an unacceptable risk to patients, users or public health.

  6. The manufacturer must comply with the MDR's post-market surveillance, vigilance, registration and economic operator obligations.

In addition, Regulation (EU) 2023/607 removed the "sell-off" date in MDR Article 120(4) and IVDR Article 110(4); devices placed on the market during the transition period can now remain on the market without a time limit, without prejudice to their shelf life or expiry date.

IVDR Transition Period Extension

Regulation (EU) 2024/1860 rearranged the transitional provisions in IVDR Article 110; the class-based deadlines were set as follows:

  • 31 December 2027: Class D devices

  • 31 December 2028: Class C devices

  • 31 December 2029: Class B devices and Class A devices placed on the market in sterile condition

Actions TİTCK Must Take

TİTCK has published announcements No. 2023/KK-1 and 2023/KK-2 on the implementation of the provisions of EU 2023/607 in Türkiye. Under these announcements, registration / update applications in ÜTS for devices considered eligible for the transition period extension, and for the documents linked to them, are made according to specific procedures and principles. Similarly, announcement No. 2024/KK-3 has been published for the IVDR transition period extension.

During the transition extension process in ÜTS, the "Evidence Documents for MDR Transition Period Extension" field must be completed, and documents such as the agreement signed with the notified body, the MDR application letter and QMS compliance evidence are uploaded.

For a detailed article on the IVDR transition period extension process:

12. EUDAMED: European Database on Medical Devices

EUDAMED (European Database on Medical Devices) is the central electronic database established under EU 2017/745 (MDR) Article 33 and EU 2017/746 (IVDR) Article 30, providing medical device transparency, traceability and oversight across the European Union. It is managed by the European Commission.

The 6 Modules of EUDAMED

  1. Actor (Economic Operator) Module: Registration of manufacturers, authorised representatives, importers and system/procedure pack producers.

  2. UDI / Device Registration Module: Registration of devices on a UDI-DI basis.

  3. Notified Bodies and Certificates Module: NB designations and issued certificates.

  4. Clinical Investigations and Performance Studies Module

  5. Vigilance and Post-Market Surveillance Module

  6. Market Surveillance Module

EUDAMED Mandatory Date of 28 May 2026

Regulation (EU) 2024/1860 arranged for EUDAMED to become mandatory module by module. With Commission Decision (EU) 2025/2371 dated 27 November 2025, the European Commission announced the full functionality of the first four modules (Actor Registration, UDI/Device Registration, Notified Bodies and Certificates, Market Surveillance). From 28 May 2026, the end of the 6-month transition period after publication of the decision, use of the relevant modules becomes mandatory.

Actor Registration and SRN

Companies that complete EUDAMED actor registration are assigned a Single Registration Number (SRN) by the country's competent authority (TİTCK for Türkiye). The SRN is used in the EU Declaration of Conformity, in label information and in all EUDAMED module transactions.

ÜTS and EUDAMED Relationship

ÜTS and EUDAMED do not substitute for each other; both are mandatory. ÜTS is used for national product tracking and market surveillance in Türkiye, while EUDAMED is used for transparency and traceability across the EU. Under TİTCK's Circular No. 2024/2 on Medical Device Regulations dated 04.06.2024, manufacturers, importers, authorised representatives and system/procedure pack producers in Türkiye must carry out EUDAMED actor registration. The contact details entered during EUDAMED actor registration must match the information in ÜTS and ÇKYS exactly.

For a detailed article on the EUDAMED registration process:

13. Custom-Made Medical Devices and ÜTS

A custom-made medical device is a device specially designed and manufactured for the individual needs of a specific patient on the basis of a written prescription by a person authorised by national legislation. Article 2/u of the Tıbbi Cihaz Yönetmeliği and MDR Article 2(3) contain this definition.

Custom-Made Device Examples

  • Dental prostheses, crowns, bridges, implant superstructures

  • Custom-made eye prostheses

  • Patient-specific orthopaedic corsets, orthoses and prostheses

  • Custom-made hearing aids

  • Hasta-spesifik cerrahi rehberler

  • Custom-made implants (Class III implantable devices)

Legislation for Custom-Made Devices

  • Tıbbi Cihaz Yönetmeliği Annex XIII (Procedure for custom-made devices)

  • Ismarlama Protez ve Ortez Merkezleri ile İşitme Cihazı Merkezleri Hakkında Yönetmelik (RG: 24.09.2011 / 28064)

  • Diş Protez Laboratuvarları Yönetmeliği (RG: 07.12.2005 / 26016)

Custom-Made Device Registration in ÜTS

ÜTS has a separate registration screen for custom-made devices (the "MDR Custom-Made Medical Device Screen"). If the transition period extension under (EU) 2023/607 is to be used for Class III implantable custom-made devices, "Yes" is selected in the "Is it a Class-III implantable custom-made medical device?" field on the screen, then "Yes" is marked for the question "Has an application been made under Announcement No. 2023/KK-1?" and the necessary documents are uploaded to the "Evidence Documents for MDR Transition Period Extension" field.

On the EUDAMED side, according to the statement made by the European Commission, legacy and custom-made medical devices are not registered in the UDI / Device module; they are only referenced in market surveillance files.

14. Other Important Processes Under ÜTS

Free Sale Certificate (FSC)

A document requested when Turkish manufacturers export abroad, proving that the manufacturer is legally authorised to sell in Türkiye. Applications are made through the Electronic Application System (EBS) and ÜTS.

Advertising and Promotion Records

Under the Tıbbi Cihaz Satış, Reklam ve Tanıtım Yönetmeliği, promotional activities aimed at healthcare professionals, product sample distribution, scientific meeting sponsorships and clinical support activities are notified to ÜTS.

Vijilans (Olumsuz Olay Bildirimi)

Under Articles 87-92 of the Tıbbi Cihaz Yönetmeliği, serious incidents and field safety corrective actions (FSCA) are reported to TİTCK through the ÜTS Vigilance module.

Testing, Control and Calibration

Under the Tıbbi Cihazların Test, Kontrol ve Kalibrasyonu Hakkında Yönetmelik, medical devices in use are tested, controlled and calibrated by organisations that have been issued an authorization certificate, and the reports are entered into ÜTS.

15. Most Common Mistakes in ÜTS Processes

According to official data, the most frequent reasons for rejection by TİTCK:

  1. Missing or incorrect CE certificate (suspended or withdrawn NB certificates, or certificates whose scope does not match).

  2. Invalid / incorrect GMDN and EMDN codes.

  3. Declaration of conformity not compatible with the MDR (missing Basic UDI-DI, old directive references).

  4. Missing Turkish label and instructions for use (MDR Annex I, Section 23).

  5. Deficiency in the authorised representative agreement (for manufacturers established outside Türkiye or the EU).

  6. No PRRC appointment having been made.

  7. Registration applications made by personnel without a TCKE certificate (after 01.01.2025).

  8. ÇKYS number missing or becoming passive.

  9. Inability to prove the (EU) 2023/607 transition period conditions.

  10. Incorrect determination of the risk class (especially devices up-classified in the transition to the MDR).

16. ÜTS Processes with Medex Kurumsal Danışmanlık

Medex Kurumsal Danışmanlık provides companies operating in the medical device and in vitro diagnostic field with ÜTS company registration, document registration, medical device product registration, EUDAMED actor registration, MDR / IVDR compliance processes, CE certificate extension applications, custom-made device registration and import-export regulation services. Thanks to our many years of experience in the sector, our up-to-date tracking of legislation and our methodology of working in integration with TİTCK, your applications are completed quickly, without errors and in full.

Medex's ÜTS Service Scope

  • ÜTS Company Registration and Activation

  • Medical Device Sales Center Authorization Certificate Application

  • TCESİS Training Guidance and Exam Preparation (SM, STE, KDE, TCKE)

  • Person Responsible for Regulatory Compliance (PRRC) Appointment

  • EC / CE Certificate and Declaration of Conformity Document Registration

  • Medical Device / IVD Product Registration (MDR & IVDR)

  • GMDN and EMDN Coding Support

  • UDI / Basic UDI-DI Structuring

  • EUDAMED Actor Registration and SRN Allocation

  • (EU) 2023/607 and (EU) 2024/1860 Transition Period Extension Applications

  • Custom-Made Medical Device Registration (Including Class III Implants)

  • Label, Instructions for Use and Turkish Localization Compliance

  • Vigilance and Post-Market Surveillance Processes

  • Free Sale Certificate (FSC) Application

  • Import and TAREKS Process Management

  • SGK / MEDULA Reimbursement Applications

  • Medical Device Classification and Scope Determination Service

For the current steps of company, document and product registration, see our ÜTS registration guide; for having the registrations carried out on your behalf, see our ÜTS consultancy page.


17. Frequently Asked Questions About ÜTS (FAQ)

What does ÜTS mean? ÜTS is the abbreviation of Ürün Takip Sistemi (Product Tracking System). It is the electronic registration system managed by the TİTCK of the Republic of Türkiye Ministry of Health, in which medical devices, cosmetic products and Type-1 and Type-19 biocidal products are tracked individually in Türkiye.

Who must register in ÜTS? ÜTS registration is a legal requirement for all companies that manufacture, import, distribute, sell or apply medical devices, IVDs, cosmetics or in-scope biocidal products in Türkiye.

How long does ÜTS company registration take? The legislation does not define a binding completion time; the time varies with the completeness of the documents and the workload of the institutions concerned. Missing documents, incorrect information or a delay in the Provincial Health Directorate Authorization Certificate can extend the process.

Can ÜTS registration be made without a CE certificate? For Class I devices (non-sterile, without a measuring function, and not reusable surgical instruments), the manufacturer can register with its own EU Declaration of Conformity. For Class IIa, IIb, III and IVD Class B/C/D, a valid CE certificate issued by a notified body is mandatory.

Does a medical device without ÜTS registration clear customs? No. The TAREKS system automatically rejects products without ÜTS registration. Even with payment of the VAT difference, importing a medical device without ÜTS registration is not possible.

What is the difference between MDR and MDD? MDD (93/42/EEC) is the EU's previous medical device directive. MDR (EU 2017/745) is the regulation that replaced the MDD as of 26.05.2021. The MDR introduced innovations such as stricter clinical data, the UDI system, EUDAMED, PRRC, more comprehensive post-market surveillance and the up-classification of some devices.

Is EUDAMED registration mandatory? Yes. Under Commission Decision (EU) 2025/2371, from 28 May 2026 the use of the first four EUDAMED modules becomes mandatory for all economic operators. Manufacturers, importers, authorised representatives and system/procedure pack producers in Türkiye are obliged to carry out EUDAMED actor registration under TİTCK Circular No. 2024/2 dated 04.06.2024.

Does EUDAMED registration replace ÜTS registration? No. ÜTS is national and EUDAMED is at EU level. Both are independent requirements and the information must be kept consistent.

Who does the MDR transition period extension cover? Manufacturers holding a valid MDD/AIMDD certificate issued before 20 March 2023 who meet the conditions set in (EU) 2023/607 (MDR application by 26.05.2024, agreement with an NB by 26.09.2024, MDR-compliant QMS, no significant design change, etc.) can benefit from the extension until 26.05.2026, 31.12.2027 or 31.12.2028, depending on the class.

What are the IVDR transition dates? Under Regulation (EU) 2024/1860: 31.12.2027 for Class D, 31.12.2028 for Class C, and 31.12.2029 for Class B and sterile Class A.

Are custom-made medical devices registered in EUDAMED? According to the European Commission's statement, custom-made and legacy medical devices are not registered in the UDI / Device module; they are only referenced in market surveillance files. In ÜTS, there is a separate registration screen for custom-made devices.

Who can make ÜTS registrations? Under the regulation amendment dated 26.05.2023, from 01.01.2025 medical device registration in ÜTS can only be made by persons holding the Medical Device Registration Staff (TCKE) qualification certificate. Applications by personnel without a TCKE certificate are not accepted.

Is there a fee for ÜTS company registration? TİTCK does not charge any fee for company registration. However, the process involves costs such as the Provincial Health Directorate Authorization Certificate, training and exam, e-signature and NB fees.

How long does medical device product registration take? The process is generally shorter for Class I devices; Class IIb and III devices take longer because they are subject to TİTCK expert review. The legislation does not define a binding review time.

18. Conclusion

ÜTS (Product Tracking System) is the backbone of the medical device market in Türkiye. All processes such as ÜTS company registration, document registration, medical device product registration, EUDAMED integration, MDR and IVDR transition processes, custom-made device registration and CE certificate extension are interconnected, dynamic and strictly tied to legislation. A mistake in one step can have serious consequences, from being unable to enter tenders to a device being stuck at customs, from SGK reimbursement stopping to the company becoming passive.

As Medex Kurumsal Danışmanlık, we are by your side with a fast and transparent consultancy service that is in exact compliance with official legislation, TİTCK announcements and EU regulations. You can entrust all your regulatory processes, from ÜTS company registration to EUDAMED integration, to our professional team.

You can follow all our ÜTS and medical device legislation guides by topic on the ÜTS Guide Index page.

For your ÜTS company, document and product registration: Medical Device ÜTS Registration Consultancy

 
 

Medical Device ÜTS Registration Consultancy

Request an ÜTS registration consultancy quote

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.

bottom of page
WhatsApp Hemen Ara