ÜTS Setup for a Newly Established Medical Firm

You have set up the company, you are ready to import your first product, but when you enter UTS the screens you are looking for do not open.

ÜTS Setup for a Newly Established Medical Firm

Setting Up ÜTS for a New Medical Company

You have set up the company, you are ready to import your first product, but when you enter ÜTS you see that the screens you are looking for do not open. The problem is usually not missing information but the order: in ÜTS each step opens only after the previous one is completed, and you cannot start from the middle of the chain.

This page explains the order of the setup, which document is collected at which step, and which part of the work you can hand over. The screen-by-screen steps are not here; they are on our page describing how company registration in ÜTS is done. The references are to the TİTCK document "Procedures for Registration in the Medical Device Tracking System (Guide)" (TCKKD-KLVZ-03), the Medical Device Regulation, and the Medical Device Sales, Advertising and Promotion Regulation.

If the order is wrong, the next screens do not open

The place newly established companies lose the most time is starting from the middle of the chain. Before opening the product registration screen and trying to enter a barcode, the three steps that open it must be completed.

The chain works as follows: a medical device sales centre licence is obtained, a ÇKYS number is generated under the licence, the company is registered in ÜTS, the company's users and signatory are defined, documents are registered, and only after this can the device be registered.

The link between the last two links of the chain is written explicitly in the Guide. Under sub-item (a) of paragraph 5 of Article 25 of the Guide, the documents to be added to a device are selected from among the documents in "Registered" status in ÜTS as a result of an application made under Article 39. Sub-item 3 of the same sub-item adds one more step: the class of the device must be selected before a document is selected, and the selection is made from the documents that can be selected for the device's class.

In practice this means that you cannot complete the product registration until your documents are "Registered". Your documents must also enter review through an application of yours. So the registration of your first product is in fact the registration of your first document application.

The first link of the chain also cannot be skipped. Under paragraph 1 of Article 5 of the Guide, companies carrying out the sale and/or application of medical devices may be registered in ÜTS only if they are authorised under the relevant legislation. Authorisation is not done inside ÜTS; it is a procedure carried out with the Provincial Health Directorate. For this reason, when planning the setup calendar, it must be accepted from the start that the first item is not ÜTS.

The source of company registration: MERSİS, VEDOP or EBSBefore registering in ÜTS you need to know which source your registration will be fed from. Under paragraph 2 of Article 5 of the Guide, company registrations are made on the basis of MERSİS or VEDOP. If a company has both a MERSİS and a VEDOP number, the transaction is carried out using the MERSİS number. Company registration for pharmacies is made on the basis of EBS.

Whether physical documents are needed also depends on the company type. Paragraph 3 of the same article states that when the company type "Company with MERSİS registration" or "Sole proprietorship company not registered with MERSİS" is selected, no physical documents are required in the application. For most newly established limited and joint-stock companies, this is the easiest part of the process.

Exception: joint ventures

If you are setting up a joint venture, your ÜTS registration is not completed on screen alone. Paragraph 3 of Article 5 of the Guide requires, in addition to the EBS application, two documents to be sent to the Authority.

Joint venture agreement: the original or a notarised copy of the agreement is sent.

Signature circulars or signature declarations: the originals or notarised copies of the signature circulars or signature declarations of the persons named in the joint venture agreement are sent.

Sending route: the documents are sent through EBS to the Authority, to the Medical Device Registration and Coordination Department, together with the standard petition given in Annex 1 of the Guide.

Paragraph 4 of the same article governs what happens to the documents: if the registration application concludes negatively, the physical documents are returned to the company with a covering letter; if it concludes positively, the originals are not returned and are kept in the Authority's archive. For this reason, keep a copy of the documents you send.

The company type determines the whole process"Firm" is not a single thing in ÜTS. Sub-item (o) of paragraph 4 of the Guide defines a company as a party carrying out the sale and/or application of medical devices, including medical device sales centres, manufacturers, importers, distributors, exporters, optical establishments, hearing device application centres, made-to-measure orthosis and prosthesis application centres, pharmacies, pharmacy warehouses and similar.

For a company bringing devices from abroad, the correct type is "Manufacturer/Importer/Distributor/Exporter", and this type comes with a condition. Paragraph 5 of Article 5 of the Guide states that companies registering in ÜTS under this type must hold a medical device sales centre licence, and that the ÇKYS number must be entered mandatorily during company registration.

The same paragraph corrects a misunderstanding. With the amendment published in the Official Gazette on 26/5/2023, the "Medical Device Sales Centre Authorisation Certificate" is not required for places where devices listed in Annex 3 of the Medical Device Sales, Advertising and Promotion Regulation are sold, except for manufacturers or importers. The Guide then states clearly that this exception does not remove the obligations set by the Medical Device Regulations. As an importer you are outside this exception.

The first steps the company takes at setup

The work of the first week is done outside ÜTS. Without sales centre authorisation you cannot fill in the ÇKYS field in your ÜTS company registration.

Article 5 of the Medical Device Sales, Advertising and Promotion Regulation requires a real or legal person who wishes to be authorised as a sales centre to apply to the directorate by petition and to submit certain documents with the petition.

Responsible director contract: under sub-item (a) of paragraph 2 of the same article, where the operator of the sales centre is not the responsible director, a written service contract concluded between the operator and the responsible director is submitted.

Personnel documents: under sub-item (b), the documents of the responsible director, the sales and promotion officer and any clinical support officer that the sales centre will employ, issued under Article 35 of the Regulation, are submitted.

Commercial registration documents: under sub-item (c), a copy of the Turkish Trade Registry Gazette, the tax certificate and the registration certificate are submitted.

Undertaking: under sub-item (ç), an undertaking is submitted that the devices the sales centre will sell and promote are registered in the Authority's registration and information management system.

Workplace opening and operating licence: under sub-item (d), the licence obtained from the relevant authority is submitted. If the place to be authorised is in a free zone, technopark or organised industrial zone, the document issued by the management of that place is accepted; if the applicant is a drug warehouse, the drug warehouse licence issued by the Authority is valid.

In the same week two preparations are made on the ÜTS side. The first is securing an e-signature for the signatory: under paragraph 13 of Article 39 of the Guide, document applications are signed electronically by the company's applicant signatory. The second is the e-mail address you will register in ÜTS: under paragraph 2 of Article 42 of the Guide, when an accrual arises in applications for the free sale certificate, the payment reference number is sent to the e-mail address registered by the company in ÜTS. In practice, this address should be a corporate, regularly monitored address rather than a personal one, which prevents notifications from being missed.

Training requirement for the person who will register in UTSThe "we will do it ourselves" decision has a hidden cost, and that cost is written in the regulation. Paragraph 10 of Article 26 of the Medical Device Sales, Advertising and Promotion Regulation states that persons who carry out medical device registration transactions in the Authority's registration and information management system on behalf of a sales centre must successfully complete the training determined by the Authority.

This provision ties the person entering the registrations to a competence requirement. In a newly established company this means either waiting for a staff member to complete the training, or handing the registration work to a party that meets this requirement. If you choose the second route, you define a user of the "Medical Device Registration Officer" type for us from your company page and the registrations run through that user.

Article 28/A of the same Regulation governs the continuity of this competence. Paragraph 2 of that article states that if repeated transactions in the registration and information management systems contrary to the procedures and principles determined by the Authority are established, the training completed by the persons carrying out those transactions under paragraph 10 of Article 26 will be cancelled.

Four questions to answer before registering your first product

Before you sit down at the product registration, the answers to four questions must be in your hand. If you do not have these answers, you cannot proceed on screen; if they are wrong, the application will conclude negatively.

What is the class of the device? Under sub-item 3 of sub-item (a) of paragraph 5 of Article 25 of the Guide, the class of the device must be selected before a document is selected.

Under which regulation is the device certified? Under paragraph 1 of Article 6 of the Guide, the "EC Certificate" document type is used only for certificates under the former Medical Device Regulations; under paragraph 1 of Article 7, the "EU Certificate (MDR/IVDR)" document type is used for certificates under the new Medical Device Regulations. Selecting the wrong type opens the wrong screen from the start.

Which allocation body issued the barcode? Under paragraph 2 of Article 27 of the Guide, for devices under the MDR the UDI allocation bodies defined in ÜTS are GS1, HIBCC, ICCBBA and IFA. For the former regulations, under paragraph 2 of Article 25, GS1, HIBCC and ICCBBA are defined.

On which side is the first issue date of the declaration of conformity? Paragraph 8 of Article 10 of the Guide states that for declarations of conformity issued for devices under the MDD or AIMDD, the first issue date must be before 26/05/2021; paragraph 9 states that for devices under the IVDD this threshold is 26/05/2022.

Splitting the first product portfolio into applications

New companies generally try to send the whole catalogue in a single application. The Guide does not permit this, and the limits vary by application type.

Document application: under paragraph 15 of Article 39 of the Guide, a document application contains at most 5 document notifications.

Standard device application: under sub-item (ğ) of paragraph 5 of Article 40 of the Guide, such device applications contain at most 500 medical device notifications.

Made-to-measure medical device and system or procedure pack application: under sub-item (d) of paragraph 6 of the same article, such applications contain at most 5 medical device notifications.

The limits do not stop there. Paragraph 7 of Article 40 states that for device applications under the former regulations, applications may be made only for devices linked to the same GMDN code; paragraph 8 states that for applications under the new regulations, except for made-to-measure devices, applications may be made only for devices linked to the same Basic UDI-DI code.

One more restriction usually comes last. Under sub-item (c) of paragraph 5 of Article 40 of the Guide, medical device applications can consist only of devices linked to a single declaration; more than one declaration of conformity cannot be selected on the application screen. So the scope of an application is the intersection of three things: a single declaration, a single GMDN or a single Basic UDI-DI, and the number limit. We work out the splitting plan by solving these restrictions together, and we give you a list showing which barcode goes into which application.

The five most common mistakes made by new companies

Each of the five mistakes below has a counterpart in the Guide, and each appears in the first portfolio.

Opening the registration with a carton barcode instead of the smallest unit: sub-item 6 of sub-item (b) of paragraph 2 of Article 25 of the Guide states that the device registration is made with the barcode allocated to the smallest package placed on the market. Barcodes of multi-product sales packs are added with their content quantities to the "Market Placement Information" field after the registration is completed.

Not checking whether the notified body is defined in ÜTS: under paragraph 7 of Article 6 of the Guide, if the notified body that issued the certificate is not defined in ÜTS, a request must be opened from the "Submit Request" screen under the "Notified/Conformity Assessment Body Transactions" field before the document application. This request must be opened before the document application.

Spending unnecessarily on the Authorised Distributorship Certificate: paragraph 9 of Article 23 of the Guide states that the Authorised Distributorship Certificate is not a mandatory document to be uploaded to ÜTS; it is an optional document, and even if it falls into rejected status, the linked devices remain registered.

Assuming ISO 13485 is mandatory: paragraph 9 of Article 21 of the Guide sets the same rule for the "Quality Management Certificate – ISO-13485". This document is also optional, and if it falls into rejected status, it does not drop the linked devices.

Trying to register spare parts as products: sub-item 5 of sub-item (z) of paragraph 7 of Article 25 of the Guide states that only products falling within the definition of "Device" and parts defined as accessories are registered in ÜTS; parts defined as spare parts are not registered in ÜTS.

Documents to request from the foreign manufacturer in the first correspondence

The content of the first correspondence determines the speed of the next three months. Asking for the following at the outset prevents writing the same e-mail three times.

Declaration of conformity and certificate, if any: under paragraph 1 of Article 12 of the Guide, for declaration of conformity notifications made by importer companies relating to a foreign manufacturer, the complete original with its annexes must be uploaded to the "Original Document" field, in the form of an apostilled document, a document approved by the Turkish embassy or consulate, an e-Apostilled document, or the original of a document e-signed by the manufacturer. On the certificate side, Article 8 of the Guide accepts, under certain conditions, a copy certified by a Turkish notary.

Most current instructions for use: under paragraph 1 of Article 18 of the Guide, the most current original instructions for use found in the technical file of the relevant medical device must be uploaded to the "Original Document" field. Asking the manufacturer for the "current version in the technical file" prevents receiving a marketing brochure.EU authorised representative mandate: under sub-item (a) of paragraph 7 of Article 12 of the Guide, for "EU Declaration of Conformity (MDR/IVDR)" notifications belonging to manufacturers established outside an EU member state or Türkiye, an entry in the "EU Authorised Representative" field is mandatory. Sub-items (b) and (c) of the same paragraph require the original of the agreement or mandate between the manufacturer and the representative, together with a sworn Turkish translation; no apostille or embassy approval is required for this document.

Distributorship certificate, if you wish: under paragraph 1 of Article 23 of the Guide, this document is issued by the manufacturer on behalf of importer companies operating in our country. It is not mandatory; it is meaningful for companies that want commercial protection.

Update on 2026/KKB-2: with TİTCK's Announcement No. 2026/KKB-2 dated 02.11.2026, a new route has been introduced in place of the option to upload the foreign manufacturer's e-signed original document for declarations of conformity and SİP declarations:

The option has been decided to be applied whereby the document is uploaded to the relevant field in ÜTS together with a commitment signed electronically by the importer company's authorised person, using an e-signature (secure e-signature) created on the basis of a qualified electronic certificate obtained from an electronic certificate service provider recognised by Türkiye, in the case where the document is to be signed electronically by the authorised person of the importer company designated by the foreign manufacturer.

Source: TİTCK Announcement No. 2026/KKB-2. Required documents and steps: ÜTS document registration guide.

Obligations that continue after registration

When the first registration is complete, the work does not end. Three obligations remain on your calendar after registration is completed.

Update within one week: paragraph 4 of Article 31 of the Medical Device Regulation requires economic operators to update the data in the electronic system within one week of any change to the registration information.

Periodic confirmation of data: paragraph 5 of the same article requires economic operators to confirm the accuracy of the data within 1 year of submitting the information, and every 2 years thereafter. If the confirmation is not made within 6 months after these periods end, the Authority may take appropriate corrective measures.

Ten-year record retention: paragraph 3 of Article 31 of the Medical Device Sales, Advertising and Promotion Regulation requires the information of the previous and, where applicable, the next economic operator in the supply chain to be kept regularly by batch, serial, lot, brand and model parameters, and these records to be retained for at least ten years from the date the device is first placed on the market.A change of obligation may also come through ÇKYS. Paragraph 7 of Article 5 of the Guide states that where the company's responsible director, title or address changes, if this information is updated in ÇKYS, the changes will be updated automatically in ÜTS. Paragraph 6 states that in company transfers and mergers, the signatories and users defined in ÜTS must be updated for ÜTS activities to continue.

Services included in the setup

The licence application, the responsible director contract and obtaining the e-signature remain with you, as these are the company's own legal transactions. On the ÜTS side, you define a user of the "Medical Device Registration Officer" type for our staff from your company page. Under paragraph 11 of Article 39 of the Guide and sub-item (f) of paragraph 5 of Article 40, only users of this type may carry out the "Approve" action for document and device applications.

With this authority we set up the document notifications, the device registrations and the application splitting plan. The e-signature stays with you: under paragraph 13 of Article 39 of the Guide and sub-item (g) of paragraph 5 of Article 40, an application in "Awaiting Signature" status is signed electronically by the company's signatory. Responsibility for the accuracy of data stays with the company as well: paragraph 4 of Article 31 of the Medical Device Sales, Advertising and Promotion Regulation keeps responsibility for the accuracy of information about devices recorded in the system with the sales centre that makes the product registration. We do not give a commitment on how long the applications will take to conclude; the Guide contains no such completion period.

Medical Device ÜTS Registration Consultancy

Request an ÜTS registration consultancy quote

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.

bottom of page
WhatsApp Hemen Ara