SUT Code and Barcode Matching

Your product is registered in ÜTS but is not progressing on the reimbursement side. Or you will apply for SUT matching and your ÜTS registration will carry this application and

SUT Code and Barcode Matching

SUT Code and Barcode Matching: UTS Compliance for Products Registered in UTS

Your product is registered in UTS, but it is not moving forward on the reimbursement side. Or you will apply for SUT matching and do not know whether your UTS record can carry that application. The first requirement of the reimbursement route is a clean and complete UTS record. If the catalogue is not uploaded, the images do not meet the standard, or the product name does not match the name in the document, the problem lies in your own record, not on the SGK side.

This page explains the preparation work on the UTS side for matching: which fields are mandatory, which document and images are requested, how the work is run across a portfolio, and what we need from you. The Social Security Institution's own application procedure is outside the scope of the registration guideline this page is based on. What is described here is preparing the UTS record for that application.

The first condition of reimbursement: a complete UTS record

Being visible on screen is not enough. Under Article 40, first paragraph of the Guide, for a device to become "Registered" in UTS, a device registration application must be made to the Institution so that the registration notice can be assessed for compliance with the regulation. A notice whose application has not been completed is not treated as a valid registration, even if it sits in the system.

There is a clear example of how the status affects other procedures. Under Article 42, second paragraph, point (ı) of the Guide, the devices in a free sale certificate application must be in "Registered" status in UTS, and if a device in the application is in "Rejected" or "Individual Product Exists in System" status, the application will be rejected by the Institution. In reimbursement preparation the same logic applies: the status of the record determines every step that rests on it.

It is also clear which barcode the record is based on. Under point (b) of the second paragraph of Article 25, sixth sub-point, and the equivalent provision of Article 27, the device is registered in UTS with the barcode of the smallest package placed on the market. Carton or multi-pack barcodes are not the registration barcode; they are added as market placement information after the registration is complete.

The "SUT Matching Status" field is mandatory in UTS

This field is not an optional tick; it is one of the mandatory fields on the registration screen, and it appears under all three frameworks. Point (v) of the seventh paragraph of Article 25 of the Guide defines it for the former regulations, point (bb) of the seventh paragraph of Article 27 for the MDR, and point (v) of the seventh paragraph of Article 30 for the IVDR.

The field has three values, each indicating a different status.

  • Match Exists: selected if the device is within SGK reimbursement coverage.
  • Matching To Be Made: selected if a SUT matching application will be made to bring the device into reimbursement coverage.
  • No Match: selected if the device is not within SGK reimbursement coverage.

The selection can be corrected later, but it does not correct itself. The list of data fields that can be made the subject of a change request under the seventh paragraph of Article 44 of the Guide shows that not every field can be freely corrected after registration. For this reason, marking the reimbursement intention correctly at the time of registration takes less work than running a separate change request later.

A Turkish catalogue is mandatory where a SUT matching application will be made

This is the single condition most often missed in reimbursement preparation. Point (v), fifth sub-point of the seventh paragraph of Article 25 of the Guide, point (bb), fifth sub-point of the seventh paragraph of Article 27, and point (v), fifth sub-point of the seventh paragraph of Article 30 all say the same thing: for devices for which a SUT matching application will be made, a Turkish catalogue must be uploaded to UTS.

The catalogue is also defined. Under the first paragraph of Article 24 of the Guide, a Turkish catalogue containing information such as images, a short description and reference, catalogue, version or model that identifies the device may be uploaded. The catalogue is not a marketing brochure; it is a Turkish document that defines the device through these parameters.

There is one convenience. Under the second paragraph of Article 24 of the Guide, catalogues uploaded are recorded in UTS without being checked by a review specialist. This does not mean the content of the catalogue is unimportant; it only shows that uploading the catalogue does not create a separate review step.

What the choice "Will It Be Sold in the Health Market / Will SGK Reimbursement Be Made?" triggers

This field is also mandatory under all three frameworks: for the former regulations under point (y) of the seventh paragraph of Article 25 of the Guide, for the MDR under point (cc) of the seventh paragraph of Article 27, and for the IVDR under point (y) of the seventh paragraph of Article 30. The field is selected as "Yes" where the device will be sold within the Health Market set up under the State Supply Office, or reimbursed by SGK.

When "Yes" is selected, a separate image standard applies. Point (çç) of the seventh paragraph of Article 27 of the Guide, the first sub-point of point (y) of the seventh paragraph of Article 25 (third sub-point), and the first sub-point of point (z) of the seventh paragraph of Article 30 define this standard in the same way.

  • Minimum number: at least 3 photographs for each device.
  • Packaging types: for devices with inner and outer packaging, at least 3 photographs of each packaging type.
  • Components: where they exist, images of spare parts, consumables, accessories and all components of the device must also be included. The example the Guide gives is a three-part syringe: body, needle tip and needle cap.
  • Technical criterion: each photograph must be at least 600x600 pixels, square, no more than 2 MB, and in jpeg, jpg or png format.
  • Angles: photographs must show all details according to how the device is used, taken from different directions.

This standard is the longest item in the portfolio for large companies. We do not do the photography ourselves; we check conformity with the standard and report back to you the items that do not meet it.

Additional area for devices paid by surface area

For some devices, reimbursement is paid by surface area rather than by unit. For these devices an additional field is completed on the registration screen.

Under point (ff) of the seventh paragraph of Article 27 of the Guide, surface area information is a value that must be entered for devices reimbursed by surface area under SGK reimbursement procedures, and for these devices the area is entered in square centimetres. The same point states that for devices not paid by surface area, or outside reimbursement coverage, this field may be left empty.

This field can be corrected later, but it requires a separate process. Under the seventh paragraph of Article 44 of the Guide, "Product Surface Area (in cm2)" is among the data fields that can be made the subject of a change request.

Grounds for rejection of images

Uploading images seems easy, which is why it is underestimated; yet the Guide sets a separate set of rules for this field. Point (a) of the sixth paragraph of Article 25 and point (a) of the sixth paragraph of Article 27 of the Guide contain the same provisions.

  • Unclear image: if images that are not sharp or are unreadable are uploaded, the application will be rejected.
  • The catalogue itself: the catalogue itself, or an image containing more than one device that makes the device hard to identify, is not uploaded as a product image.
  • Image of another device: only photographs and technical drawings of the relevant device are uploaded to this field; images of other devices, even similar ones, are never uploaded.
  • File name: image file names must describe the device and the image; commercial extensions and expressions such as "WhatsApp" must not appear in image names.
  • Quantity limit: a maximum of 10 images may be uploaded to the product images field.
  • Packaging only: the packaging of the device on its own is not uploaded as the product image; photographs or technical drawings clearly showing the device are uploaded together with packaging images.

The last rule has one exception. Under the sixth sub-point of point (a) of the sixth paragraph of Article 25 of the Guide, where opening the device package would impair its sterility or reliability, and/or the device is in liquid form, only a packaging image may be uploaded to this field.

The barcode-catalogue file needed before matching

We run portfolio preparation through a single file. What we need is three items:

  • One Excel list: a list on which the barcode, product name, version or model and the reference or catalogue number are matched on the same row. Under the second paragraph of Article 27 of the Guide, these fields are set out under the heading of identifying information; we align the list exactly with these fields.
  • Turkish catalogue and images: a Turkish catalogue file that complies with the first paragraph of Article 24 of the Guide, and at least three photographs per product that meet the criteria in point (çç) of the seventh paragraph of Article 27.
  • Surface area values: for products paid by surface area, values in square centimetres.

When we receive this file, the first thing we do is compare each row with its counterpart in the documents. We return the rows that do not match with a correction suggestion; the authority to change what is written in the document rests with the manufacturer, not with us.

The matching process for multi-product portfolios

For portfolios with hundreds of barcodes we do not do the catalogue and image work one by one. Under the first paragraph of Article 35 of the Guide, device information that may be updated without an application, such as associating a new catalogue or uploading a new product image, may be entered in bulk through the "Bulk Update Product Without Application" screen on the registration page.

This screen has its own rules, and a bulk operation carried out without knowing them leaves a table that is hard to correct.

  • An empty catalogue list breaks the link: under the fourth paragraph of Article 35 of the Guide, the "Product Catalogue List" field in the template must contain the name of every catalogue that is to be linked to the device and is registered in UTS under Article 24. If this field is left empty and the device already has a linked catalogue before the operation, the link between the device and the catalogue is broken. If the device has no catalogue, the field is left empty.
  • The catalogue condition for reimbursement: under the fifth paragraph of the same article, if the "Will It Be Sold in the Health Market / Will SGK Reimbursement Be Made?" field is marked "Yes" in the template, the device must have a total of at least 3 images, including the new images to be added.
  • Zip structure: under the sixth and seventh paragraphs, the template Excel file and the images are compressed into a single zip file; the files sit directly inside the zip file, not in separate folders within it.
  • File names: under the eighth paragraph, Turkish characters may not be used in file names.

Validating the template on a copy before running the bulk operation is the step that saves the most time in practice. A single wrongly built column affects hundreds of records at once.

The UTS fields that are decisive in the matching file

Matching depends not on free text but on specific fields on the registration screen. The second paragraph of Article 27 of the Guide defines these fields, and sets out how each is to be completed.

  • Brand name is mandatory and cannot be left blank. Under the second sub-point of point (e) of the second paragraph of Article 27, UTS registration is not carried out for devices for which no brand is declared.
  • Product Name and Trade Name are mandatory. The eleventh sub-point of point (f) of the same paragraph requires that the information in the documents, on the label and in these fields be consistent and matching.
  • Version/Model and Reference/Catalogue Number follow a pair of rules. Under the seventh sub-points of points (ğ) and (h) of the second paragraph of Article 27, both of these fields cannot be left empty together, and "NONE" must not be written in the fields; at least one of the two fields must contain information.

There is also a prohibition on brand. Under the sixth sub-point of point (e) of the second paragraph of Article 27 of the Guide, devices carrying the same product number cannot be registered in the system under different brand names; where different companies have registered the same device under different brands, the Institution will act on the non-conforming records following its assessment.

How to change data if a correction is needed

After the registration is completed, if a field needs to change, that field must be one of the fields that can be the subject of a change request. The seventh paragraph of Article 44 of the Guide lists these fields one by one, and the list currently contains 23 data fields.

Fields that directly affect reimbursement preparation are on this list. "Product Surface Area (in cm2)", "Measurement" and "Storage Condition" are among them. The list also includes "Number of Products in Content", "Class", "GMDN", "EMDN", "Branch Type Code", and fields related to the characteristics of the device. Under the eighth paragraph of the same article, the options on this list may be changed or updated by the Institution when it deems necessary.

There is one more limit that directly affects planning. Under the ninth paragraph of Article 44 of the Guide, only one data field may be selected from the list in the same change; where a change is requested for several different data fields, a separate application is made for each data field whose change is requested. Correcting three fields means three separate requests.

Why measurement information is requested on the reimbursement side

Measurement is one of the parameters that define the device, and it is grouped under a separate heading on the registration screen. Under point (a) of the eighth paragraph of Article 25 of the Guide and point (a) of the eighth paragraph of Article 27, the "Add Measurement" screen already lists the following as measurement types: "Angle", "Weight", "Area", "Pressure", "Perimeter", "Depth", "Outer Diameter", "Width", "Total Volume", "Length" and "Height".

The same provision also sets a limit: for each measurement type, a single selection can be made from the measurement units, and more than one measurement cannot be added within the same measurement type. If the measurement type or unit you are looking for is not in the list, it can be requested from the "Request" screen; the request must be accompanied by detailed information and a reference document on the relevant measurement type.

The bulk portfolio has a separate screen for entering measurements. Under the first paragraph of Article 38 of the Guide, measurement values that are not present as a parametric data field in bulk notification templates may also be added to UTS in bulk, using the "Add Measurements to Devices in Bulk" screen. The fifth paragraph of the same article states that for a device registration or update notice made within this scope, a device application must be made to the Institution under Article 40 for the notice to be assessed. In other words, adding measurements is not a process that proceeds without application, as catalogues and images do.

Common errors in matching

Most of the errors that broke matching in the files we inherited fall under two headings.

The first is name mismatch. The second paragraph of Article 10 of the Guide for the declaration of conformity and the second paragraph of Article 11 for the EU declaration of conformity set out the same requirement: the information entered in the system must match the information in the document. When the product name is written one way in the document and another way in UTS, the record may appear valid but the matching file will not hold.

The second is entering the barcode in the wrong field. Under the sixth sub-point of point (f) of the second paragraph of Article 25 of the Guide, the Version/Model field must not contain the Primary Product Number or Secondary Product Number; the eighth sub-point of point (ğ) of the second paragraph of Article 27 repeats the same prohibition for the UDI-DI number, and the fourth sub-point of point (h) of the same paragraph says the same for the Reference/Catalogue Number field. The barcode is not information to be declared in these fields.

For the general workload on the product side, see the UTS Product Registration Consultancy page; for the full set of rules on images and labels, see the UTS Product Image and Label Rules page.

Medical Device ÜTS Registration Consultancy

Request an ÜTS registration consultancy quote

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.

bottom of page
WhatsApp Hemen Ara