Is a Stock Count Notified to ÜTS?

The legislation does not provide a separate type of notification called stock count; however, sales centres are obliged to make individual movement notifications in order to keep the information they have registered in the system up to date and to ensure traceability…

ÜTS frequently asked questions: Is a Stock Count Notified to ÜTS?

The legislation does not provide a separate type of notification called stock count; however, sales centres are obliged to make individual movement notifications in order to keep the information they have registered in the system up to date and to ensure traceability. For this reason, the records of devices in stock are expected to be consistent with their status in the system. The detailed procedures and principles for counting and correction transactions are determined by the Agency's regulations.

Content of the obligation

Article 8 of the Medical Device Sales, Advertising and Promotion Regulation places three separate obligations on sales centres: to register the devices placed or made available on the market in the Agency's registration and information management system, to keep the registered information up to date, and to make individual movement notifications to ensure the traceability of devices. Individual notification is defined as all movement notifications that must be made through the Product Tracking System from the moment the device is manufactured or imported. Article 34 of the Medical Device Regulation provides that obligations relating to the national product tracking system will be determined by regulations published by the Agency.

Other rules affecting stock records

  • The sales centre keeps records relating to its infrastructure, staff and devices in connection with its activities and complies with the Agency's registration and information management system
  • The details of the preceding and, if any, the following economic operator in the supply chain are kept in order, by parameters such as batch, serial, lot, brand and model, and are retained for at least ten years from the date the device started to be made available on the market
  • The accuracy of the information on devices registered in the system is the responsibility of the sales centre that made the product registration
  • Devices are kept under the conditions set by the manufacturer and required by international standards; the suitability of storage conditions is among the matters inspected
  • The sale of devices found to be unsafe or in breach of technical regulations within the scope of market surveillance and inspection and the warning system, and declared by the Agency, is stopped immediately and these devices are returned to their manufacturer or importer; these transactions are also reflected in stock records

Inspection perspective

On the sales centre inspection form, whether the devices sold are registered in the registration and information management system created by the Agency, and whether individual notifications have been made in this system, are inspected separately. If it is found that individual notifications have not been made, the sales centre is warned and given 15 days to remedy the deficiency; if it is found that the deficiency has not been remedied, a temporary suspension of activity sanction of 15 days is applied. During the inspection, the responsible manager must provide all requested information, documents and books. Differences between physical stock and the system record may be treated in this inspection as a finding that the information is not being kept up to date.

What to do in practice

When there is a difference between the physical count result and the system records, the notification through which, and the procedure by which, the correction will be made are determined in the regulations the Agency has published on ÜTS. The Agency issues guides on registering devices in the registration and information management system; sales centres set up the infrastructure in line with these guides within the specified periods. The current Agency regulation should therefore be checked before a count.

Common mistakes

  • Entering the physical count only in the accounting records and leaving the system record out of date
  • Not counting by lot and serial, and therefore being unable to match the difference with the system record
  • Not reflecting returns, damage or withdrawal-from-use movements in the records
  • Not separating devices declared unsafe by the Agency from stock and not recording the return process

Who it concerns: Sales centres, warehouse and stock officers, manufacturers and importers, and regulatory compliance and internal audit units. Satış merkezleri, depo ve stok sorumluları, imalatçı ve ithalatçılar, mevzuat uyum ve iç denetim birimleri.

Common mistake: Not noticing a difference between the system record and physical stock until inspection day. Sistem kaydı ile fiziki stok arasındaki farkı denetim gününe kadar fark etmemek.

Basis: Medical Device Sales, Advertising and Promotion Regulation (OG 15.05.2014-29001) ARTICLE 4, ARTICLE 8, ARTICLE 27, ARTICLE 31, ARTICLE 36, Annex-2; Medical Device Regulation (OG 02.06.2021-31499 bis) ARTICLE 34. Tıbbi Cihaz Satış, Reklam ve Tanıtım Yönetmeliği (RG 15.05.2014-29001) MADDE 4, MADDE 8, MADDE 27, MADDE 31, MADDE 36, Ek-2; Tıbbi Cihaz Yönetmeliği (RG 02.06.2021-31499 mükerrer) MADDE 34.

Notification and Follow-up

Medical Device ÜTS Registration Consultancy

Request an ÜTS registration consultancy quote

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.

bottom of page
WhatsApp Hemen Ara