ÜTS Individual Movement Notifications: Notification Types and Rules According to the TİTCK Guideline

SUMMARY
Individual movement notifications are all movement notifications made through the Product Tracking System (ÜTS) from the moment a medical device is manufactured or imported. Sales centers are obliged to make these notifications.
This article is a general map of the notification types. We give each type with its article number and as a literal quotation (unofficial translation) from TİTCK's Guideline on Individual Movement Notifications of the Product Tracking System for Medical Devices.
For regular ÜTS individual notifications: Medical Device ÜTS Registration Consultancy
Contents
1. What Are Individual Movement Notifications and Who Makes Them?2. Tracking by Serial and Lot Number3. Entry into the System: Production, Import and Inventory Notification4. Movement Within the System: Give, Receive and SİP5. Exit Notifications6. Recall Notifications7. Other Notifications8. Restrictions: Recall, Expiry Date, Passive Company9. Bulk Notification with Excel and Querying10. Frequently Asked Questions
1. What Are Individual Movement Notifications and Who Makes Them?
The Regulation on Medical Device Sales, Advertising and Promotion defines individual notification as follows:
“t) (Added: OG-2/9/2020-31232) Individual notification: All movement notifications that must be made through the Product Tracking System from the moment medical devices are manufactured or imported,”
Article 8 of the same Regulation places the obligation on the sales center:
“Sales centers are obliged to register the medical devices they place on the market or make available on the market in the registration and information management system established by the Agency, to keep the registered information up to date, and to perform individual movement notification transactions to ensure the traceability of these devices.”
The scope of the guideline is the process from the manufacture or import of the device to the end user:
“Article 2- (1) This Guideline contains the procedures and principles to be complied with in carrying out individual tracking in the Product Tracking System (ÜTS) of the products within the scope of the Medical Device Regulations, from the manufacturing/import process until they reach the end user.”
There is no separate training requirement for notification transactions. Article 11 of Guideline TCS-KLVZ-08:
“No requirement to receive training from an authorized organization is sought for the notification transactions (receiving-giving notifications, etc.) of a medical device registered in ÜTS.”
2. Tracking by Serial and Lot Number
Notifications are made through the unique identity of the device. The guideline defines the unique identity as follows:
“Unique Identity: The code containing the product number, serial/LOT number and manufacturing/expiry dates, which are the specific information of the product in the product QR code,”
“Article 5- (1) Medical devices are tracked by serial and/or lot number according to the production process determined by their manufacturer.”
“(2) Tracking medical devices by serial number means that there is only one individual product with the same unique number.”
“(3) Tracking medical devices by lot number means that there is more than one individual product with the same unique number.”
“(4) For products tracked both by serial and lot, tracking is carried out in the system by serial number.”
“(5) For products with the same product number and the same lot number, entering different manufacturing and expiry dates in the system is not permitted.”
“(6) In the product movement notifications of medical devices registered in ÜTS, the primary product number of the medical device or the market placement barcode added to the primary product number may be used.”
For what the primary product number is and where it appears on the device label, see: What is the primary product number and where is it written?
3. Entry into the System: Production, Import and Inventory Notification
Production Notification (Article 6)
“Article 6- (1) A "production notification" is made for products whose country of origin in the product registration is "Türkiye".”
“(2) The manufacturer company makes a production notification only for medical devices that are registered in ÜTS or that meet the conditions announced by the Agency within the transitional provisions of the Medical Device Regulation.”
Mandatory fields:
“Lot and/or serial number”
“Quantity information when only the lot number is entered”
“Manufacturing date or Expiry date”
Import Notification (Article 7)
“Article 7- (1) An "import notification" is made for products whose country of origin in the product registration is not "Türkiye".”
“(2) If the country of origin includes another country in addition to "Türkiye", a production or import notification may be made.”
“(3) The import notification transaction may be made by the importer together with the dealer authorized by the importer.”
In an import notification, the "Country imported from" and "Country of origin" fields are mandatory in addition to the fields in the production notification (Article 7, fifth paragraph). Production and import notifications made in error are withdrawn with a cancellation notification.
Inventory Notification (Article 8)
“Article 8- (1) For fixed-asset medical devices that are within healthcare service providers and medical service providers and are subject to maintenance, repair and calibration, an inventory notification is made in ÜTS by healthcare service providers and medical service providers.”
For the steps of the inventory notification and calling the product number from TİTUBB, see our article on ÜTS inventory notification.
4. Movement Within the System: Give, Receive and SİP
“Article 9- (1) When individual products owned by an institution/company/hospital are to be given to another institution/company/hospital, a give notification is made.”
“(2) If a receive notification is not made by the counterparty institution/company/hospital in response to the give notification, the stock transfer for that product does not take place.”
“Article 10- (1) A receive notification is made to accept the give notifications made by an institution/company/hospital.”
A receive notification cannot be cancelled:
“(4) If a Receive Notification is made incorrectly, it cannot be cancelled. In order to cancel the transaction in question, a give notification must be made again to the company/institution/hospital that made the give notification, and the relevant party must receive the medical devices with a receive notification.”
For mandatory fields, the free sample marking, "I do not want to receive" and bulk receiving, see our article on ÜTS give and receive notification.
For devices registered as a System/Procedure Pack (SİP), order matters:
“Article 11- (1) Before the production notification of medical devices registered in ÜTS as System/Procedure Pack (SIP) is made, the individual notification of the sub-products defined in the SIP registration must be made.”
5. Exit Notifications
Use Notification (Article 12)
“Article 12- (1) When a medical device that is implanted in the body by a healthcare service provider and/or is within the scope of reimbursement and must be directly associated with the patient is used, a "Use Notification" is made through personally identifying patient information for that product.”
The conditions sought in the product registration for a use notification and the entry of patient information are in our article on how to make an ÜTS use notification.
Consumption Notification (Article 13)
“Article 13- (1) When products for which a use notification will not be made by the healthcare service provider are used, a "Consumption Notification" is made for these products.”
Give to Consumer Notification (Article 14)
“Article 14- (1) A "Give to Consumer Notification" is made for medical devices sold directly to citizens by the sales center.”
“(7) When a medical device sold directly to a citizen by the sales center with a Give to Consumer Notification is to be returned, a "Receive Return from Consumer Notification" is made for the number of products to be returned.”
Expiry / Loss Notification (Article 15)
“Article 15- (1) An "Expiry/Loss Notification" is made for individual products that have completed their economic life or have been lost by the institution/company/hospital.”
As the Expiry/Loss type, one of end of economic life, natural disaster, fire, theft, stock correction or other is selected. If other is selected, an explanation is entered.
Give to Undefined Place Notification (Article 16)
“Article 16- (1) A "Give to Undefined Place Notification" is made for medical devices sold to a place that cannot be defined in ÜTS (shopping mall, airport, etc.).”
The mandatory fields are Tax ID No, Document Number and the quantity given. In case of return, a "Receive Return from Undefined Place Notification" is made (Article 16, fourth paragraph).
Export Notification (Article 17)
“Article 17- (1) An "Export Notification" is made for individual products exported by the company.”
The mandatory fields are the Customs Declaration number and the quantity. For ÜTS registration in export, free zones and bonded warehouses, see our article on export, free zone and bonded warehouse ÜTS registration.
6. Recall Notifications
“Article 18- (1) A recall decision is made for a product found unsuitable for use by TİTCK or the manufacturer/importer placing the product on the market. The movement of individual products for which a recall decision has been made to the relevant institutions, to be subjected to corrective action or not to be placed on the market again, is made only with a "Recall Give Notification".”
“(2) A give notification cannot be used for individual products subject to a recall decision.”
“Article 19- (1) A "Recall Receive Notification" is made by the institution/company to accept individual products given with a recall give notification.”
“(3) A new production/import notification cannot be made for a lot number for which a recall decision has been made.”
For the place of the recall process in the legislation, see our article on market surveillance, inspection and recall.
7. Other Notifications
The sixth section of the guideline contains five more notifications:
Temporary Use (Article 20): made for individual products given to a patient for a temporary period. When the product is returned, a "Withdrawal from Use Notification" is made.
Destruction / Disposal (Article 21): made for the exit from the system of products that would endanger patient and user health.
Reprocessing (Article 22): made when an individual product defined in ÜTS is used as raw material in the production of another individual product.
Rectification / Corrective Action (Article 23): made for the rectification or corrective action applied to the product for a nonconformity determined by the institution or company.
Return to Origin (Article 24): made by the importer when it returns an individual product it imported.
“(3) Products for which there is a recall decision are not permitted to be placed on the market again without a Rectification/Corrective action notification.”
8. Restrictions: Recall, Expiry Date, Passive Company
Transactions that can be made for devices with a recall decision (Article 26):
“Recall Give and its Cancellation,”
“Recall Receive,”
“Rectification / Corrective Action and its Cancellation,”
“Destruction / Disposal and its Cancellation,”
“Removal from the Patient's Body and its Cancellation,”
“Receive Return from Consumer and its Cancellation,”
“Withdrawal from Use and its Cancellation”
For devices whose expiry date has passed (Article 27):
“Recall give notification”
“Recall receive notification”
“Destruction/Disposal Notification”
“can be made. Other notifications cannot be made apart from these.”
Companies whose company status is passive, if there is an active user in the user list, can make only give, recall give, recall receive, withdrawal from use, expiry/loss, destruction/disposal, return to origin and cancellation notifications (Article 25). Products in companies that are closed, transferred or merged are transferred through give/receive notifications.
Only production, import, export, give and receive notifications are made through the market placement barcode (Article 28). The ÜTS registration and notification transactions of sales centers whose activity is temporarily suspended are blocked for the duration of the sanction under TCS-KLVZ-08.
9. Bulk Notification with Excel and Querying
“(2) The Excel template must be uploaded to the system without any changes (without deleting columns/rows/sheets).”
For the use of the template, see our article on the ÜTS bulk notification Excel. Notifications made are queried from the "Detailed Query" menu:
“(4) Queries made under the Detailed Query menu do not include transactions made in the last hour. Transactions made within an hour can be viewed at the beginning of the next hour.”
“(2) Production and expiry dates of individual products entered incorrectly by mistake can be updated from the "Individual Products in the System" field.”
For the screen steps of notification types, see our guide on how to make an ÜTS give notification; for the ÜTS registration steps to complete before notifications, see our ÜTS registration guide; and for having notifications carried out on your behalf, see our ÜTS consultancy page.
10. Frequently Asked Questions
Is a production notification or an import notification made?
If the country of origin in the product registration is "Türkiye", a production notification is made; otherwise an import notification is made. If the country of origin includes another country together with Türkiye, either of the two may be made.
Can a receive notification made in error be cancelled?
No. According to the guideline, a receive notification cannot be cancelled. The product is sent back with a give notification to the party that made the give notification, and that party makes a receive notification.
Can a give notification be made for a product with a recall decision?
No. The movement of these products is made only with a recall give notification. A new production or import notification cannot be made for a lot for which a recall decision has been made.
Which notifications can be made for a product whose expiry date has passed?
Only recall give, recall receive and destruction/disposal notifications can be made.
Is a training certificate required to make an individual notification?
Under TCS-KLVZ-08, no requirement to receive training from an authorized organization is sought for the notification transactions of a device registered in ÜTS. The training and qualification certificate requirement is for medical device registration.
For following up and making your individual movement notifications: Medical Device ÜTS Registration Consultancy
Sources
TİTCK: Guideline on Individual Movement Notifications of the Product Tracking System for Medical Devices, Articles 2 and 4-31
TİTCK: Guideline on the Implementation of the Regulation on Medical Device Sales, Advertising and Promotion TCS-KLVZ-08, Article 11
Legislation: Regulation on Medical Device Sales, Advertising and Promotion, Articles 4 and 8