Exporting Medical Devices to Portugal: ÜTS, EUDAMED, CE and Label Language
With Decreto-Lei No. 29/2024 of 5 April 2024, Portugal renewed the language requirement and the distributor notification, and linked its national SIDM system with EUDAMED. This page brings together INFARMED's registration page, the Commission language table, MDCG 2022-16 and the ÜTS rules for a manufacturer established in Türkiye that will export medical devices to Portugal.
Mandatário: Is It Needed for Portugal
In Portuguese documents the authorised representative appears as mandatário; INFARMED's registration page says that only one mandatário can be linked to a manufacturer's devices. For a manufacturer established in Türkiye the mandatário field stays empty.
"The ’Union market’ refers to the territories of the European Union Member States, and due to the European Economic Area (EEA) is extended to Norway, Lichtenstein and Iceland, and via the Customs Union Agreement to Turkey."
Source: MDCG 2022-16 (Guidance on Authorised Representatives), footnote 1.
The Turkish footnote:
"'Union market' means the territory of the European Union Member States and is extended to Norway, Liechtenstein and Iceland because of the European Economic Area (EEA) and to Türkiye through the Customs Union Agreement."
Source: MDCG 2022-16 (Guidance on Authorised Representatives, Turkish translation), footnote 1.
MDR Article 11(1) and Article 11(1) of the Turkish Medical Device Regulation point in the same direction:
"Where the manufacturer of a device is not established in a Member State, the device may only be placed on the Union market if the manufacturer designates a sole authorised representative."
Source: (EU) 2017/745 Medical Device Regulation (MDR), Article 11(1).
"Where the manufacturer is not established in Türkiye or an EU member state, the device may be placed on the market only on the condition that the manufacturer appoints an authorised representative."
Source: Medical Device Regulation, Article 11, paragraph 1.
The Portuguese distributor is shown the EUDAMED manufacturer registration; the distributor makes the SIDM notification by linking it to the manufacturer's EUDAMED data. Authorised representation is for manufacturers established outside Türkiye and the EU.
Label and Instructions for Use Language: Portuguese (DL 29/2024 Article 40)
"Manufacturers shall ensure that the device is accompanied by the information set out in Section 23 of Annex I in an official Union language(s) determined by the Member State in which the device is made available to the user or patient. The particulars on the label shall be indelible, easily legible and clearly comprehensible to the intended user or patient."
Source: Regulation (EU) 2017/745 of the European Parliament and of the Council (MDR), Article 10(11).
The third revision of the Commission language table, dated August 2025, updated the Portugal row: label and instructions for use in Portuguese for both patient and professional users (Decreto-Lei No. 29/2024 Article 40 paragraph 3); implant card in Portuguese (Article 40 paragraph 3); declaration of conformity in Portuguese, English accepted (Article 40 paragraphs 1 and 2); field safety notice in Portuguese (Article 40 paragraph 3); conformity assessment certificates in Portuguese, English accepted. For the software interface, Portuguese is the default; an English interface can be accepted as an alternative only if the instructions for use are in Portuguese and include a translation of the information in the interface, and there is no evidence of incidents or complaints arising from an interface in a different language.
Result for a manufacturer in Türkiye: there is no English IFU option for professional use in Portugal. Since INFARMED's SIDM registration includes uploading the label, instructions for use and declaration, the Portuguese documents must be ready before the distributor's notification. For the Turkish rule, see the article on Turkish label and instructions for use.
INFARMED and the SIDM Distributor Notification
Portugal's competent authority is INFARMED (Autoridade Nacional do Medicamento e Produtos de Saúde, I.P., Lisbon); it appears for the MDR and IVDR in the Commission's May 2026 national authority list. INFARMED's device registration page (Registo de DM e DIV) gives these rules: the registration and notification obligations for medical devices are set at European level through EUDAMED; the national SIDM (Sistema de Informação para Dispositivos Médicos) has been adapted to work in coordination with EUDAMED, avoiding duplicate registration; devices registered in EUDAMED are pulled in with the UDI-DI/EUDAMED ID, and when the label, instructions for use and declaration are uploaded the device automatically receives a CDM (Código de Dispositivo Médico) and appears in the InfoDM public portal.
The distributor notification is clearly defined on the same page: without prejudice to other obligations under Regulation (EU) 2017/745, a distributor that supplies, holds, stores or provides devices for resale or for use in healthcare services, health units, pharmacies and other points of public sale (excluding direct supply to the public) transmits the information provided for in Article 28 of Decreto-Lei No. 29/2024 to INFARMED electronically for coding and inspection purposes; the same obligation applies to those who first transfer, for consideration, devices supplied directly to the public on national territory; the notification is made through SIDM. Wholesale IVD distributors notify under Article 12 of Decreto-Lei No. 189/2000.
Result for a manufacturer in Türkiye: the SIDM notification is the burden of the Portuguese distributor; the manufacturer keeps its EUDAMED registration complete and provides the Portuguese label, IFU and declaration of conformity to the distributor for the SIDM upload. The INFARMED page also says that SIDM remains in use for custom-made device manufacturers and that free sale certificates can be requested from SIDM; these two items are for manufacturers established in Portugal.
"Member States may maintain or introduce national provisions on registration of distributors of devices which have been made available on their territory."
Source: MDR, Article 30, paragraph two.
EUDAMED Registration: The Data Source of SIDM
Since SIDM pulls device data from EUDAMED, the precondition for sales to Portugal is a complete EUDAMED registration.
"Before placing a device, other than a custom-made device, on the market, manufacturers, authorised representatives and importers shall, in order to register, submit to the electronic system referred to in Article 30 the information referred to in Section 1 of Part A of Annex VI, provided that they have not already registered in accordance with this Article."
Source: (EU) 2017/745 Regulation (MDR), Article 31, paragraph one.
"Before placing a device on the market, other than a custom-made device, the manufacturer shall enter or if, already provided, verify in Eudamed the information referred to in Section 2 of Part A of Annex VI, with the exception of Section 2.2 thereof, and shall thereafter keep the information updated."
Source: MDR, Article 29, fourth paragraph.
The provision that sets the timetable:
"the obligations and requirements that relate to any of the electronic systems referred to in Article 33(2) shall apply from the date corresponding to 6 months from the date of publication of the notice referred to in Article 34(3), informing that the relevant electronic system is functional and meets the functional specifications drawn up pursuant to Article 34(1)."
Source: Regulation (EU) 2024/1860, Article 1(3)(a); amended provision MDR Article 123(3)(d) introductory sentence.
According to the Commission's EUDAMED page, Decision (EU) 2025/2371 was published in the Official Journal of the EU on 27 November 2025 and the four modules have been mandatory since 28 May 2026. The steps are in the articles on EUDAMED actor registration, EUDAMED device registration and legacy device registration; the service is EUDAMED registration consultancy.
ÜTS Export Notification and Free Sale Certificate for Portugal Shipments
Shipments to Portugal mostly go by sea to the port of Lisbon or Leixões; the ÜTS notification is tied to the export declaration in Türkiye.
"An 'Export Notification' is made for individual products exported by the company."
Source: ÜTS Individual Movement Notifications Guide, Article 17/1.
"When making an Export Notification in ÜTS, after querying by product number, lot and/or serial number, entering data in the Customs Declaration number and Quantity fields is mandatory."
Source: ÜTS Individual Movement Notifications Guide, Article 17/2.
"If the Export Notification was made incorrectly, it is cancelled with an 'Export Cancellation Notification'."
Source: ÜTS Individual Movement Notifications Guide, Article 17(3).
The notification rules are in the articles on ÜTS individual movement notifications and on exports, free zones and bonded warehouses in ÜTS; the service is on the individual notification procedures page.
A manufacturer in Türkiye obtains the free sale certificate from ÜTS, not from INFARMED.
"The Authority, for export purposes and at the request of a manufacturer or an authorised representative, shall issue a free sale certificate declaring that the manufacturer's or, as applicable, the authorised representative's place of business is registered domestically and that the device in question, bearing the CE marking under this Regulation, may be marketed in Türkiye and EU member states."
Source: Medical Device Regulation, Article 60, paragraph one.
"The free sale certificate application is made from the 'Free Sale Certificate Application Procedures' section under the 'Medical Device' tab in ÜTS."
Source: ÜTS Registration Guide, Article 42, paragraph two, item (a).
The next step is in the free sale certificate (FSC) and ÜTS article. The other half of the Iberian market: Spain.
Portugal summary table
TopicStatusCompetent authorityINFARMED, I.P. (Autoridade Nacional do Medicamento e Produtos de Saúde), LisbonLabel / IFU languagePatient and professional user: Portuguese (DL 29/2024 Article 40/3); declaration of conformity in Portuguese, English accepted (Article 40/1-2)National additional registration / notificationThe Portuguese distributor notifies INFARMED through SIDM (DL 29/2024 Article 28); SIDM pulls EUDAMED data and issues the CDM code; the manufacturer's registration is in EUDAMEDIs an AR requiredNo (manufacturer established in Türkiye, Customs Union; MDCG 2022-16 footnote 1)
Medical Device ÜTS Registration Consultancy for exports to Portugal
We handle the ÜTS product registration, export notifications and EUDAMED actor and device registration of manufacturers exporting to Portugal; we check that the Portuguese label, IFU and declaration of conformity set needed for the distributor's SIDM notification are consistent with the EUDAMED data. Get a price quote or contact us directly at +90 505 580 46 22 and info@medexmedikal.com.
Frequently Asked Questions
Who makes the SIDM notification in Portugal?
According to the INFARMED page, a distributor that supplies, holds, stores or provides devices for resale or for use in healthcare transmits the information in Article 28 of DL 29/2024 to INFARMED through SIDM. A manufacturer in Türkiye keeps its EUDAMED registration complete and provides the Portuguese documents to the distributor.
Is an English IFU enough for a professional user in Portugal?
No. According to the August 2025 revision of the Commission language table, Article 40 paragraph 3 of DL 29/2024 provides the label and instructions for use in Portuguese for both patient and professional users. English is accepted for the declaration of conformity (Article 40 paragraphs 1 and 2).
Can the software interface stay in English?
According to the Commission table, the interface in Portugal is Portuguese by default; an English interface can be accepted as an alternative only if the instructions for use are in Portuguese and include a translation of the interface information, and there is no evidence of incidents or complaints arising from an interface in a different language.
What is the CDM code, and do I need to obtain it?
According to the INFARMED page, the CDM (Código de Dispositivo Médico) is the national code given automatically in SIDM when the label, instructions for use and declaration are uploaded to a device pulled in with EUDAMED data, and it appears in the InfoDM portal. Since the registration is made by the distributor, the distributor's notification generates the code.
Do I need to appoint a mandatário for Portugal?
No. Footnote 1 of MDCG 2022-16 states that the Union market covers Türkiye through the Customs Union; MDR Article 11(1) and Article 11(1) of the Turkish Medical Device Regulation provide for an authorised representative only for a manufacturer established outside Türkiye or the EU.