Exporting Medical Devices to Bulgaria: ÜTS, EUDAMED, CE and Label Language

Bulgaria is our only EU neighbour with a land border, and a truck leaving Edirne is in Sofia within a few hours. The regulatory side is not that fast: BDA's medical device pages still publish the registration and notification forms of the Medical Devices Act (ЗМИ), and in the Commission's language table Bulgaria is marked with an asterisk for up-to-date information. This page gives the provisions that can be confirmed and clearly separates those that cannot.

Before Shipping to Bulgaria: EUDAMED

Although BDA's ЗМИ forms are still online, the place a Bulgarian importer looks for the device is EUDAMED; according to the Commission's page, the actor registration, UDI/device registration, notified bodies and certificates, and market surveillance modules have been mandatory since 28 May 2026 (notice of 27 November 2025, Decision (EU) 2025/2371). The device registration window in (EU) 2024/1860:

"no later than 12 months from the date of publication of the notice referred to in Article 34(3) in respect of the electronic system referred to in Article 33(2), points (a) and (b), manufacturers shall ensure that the information to be entered in Eudamed in accordance with Article 29 is entered in that electronic system, including regarding the following devices, provided that those devices are also placed on the market from 6 months from the date of publication of that notice:"

Source: (EU) 2024/1860, Article 1(6)(b); the amended provision is MDR Article 123(3)(e).

For a truck leaving Edirne to be accepted in Sofia, an SRN is needed first; the competent authority issues the SRN after verification (Article 31(2)):

"Before placing a device, other than a custom-made device, on the market, manufacturers, authorised representatives and importers shall, in order to register, submit to the electronic system referred to in Article 30 the information referred to in Section 1 of Part A of Annex VI, provided that they have not already registered in accordance with this Article."

Source: Regulation (EU) 2017/745 (MDR), Article 31(1).

Once the SRN is obtained, the device is registered with the Basic UDI-DI and Annex VI Part B data:

"Before placing a device, other than a custom-made device, on the market, the manufacturer shall, in accordance with the rules of the issuing entity referred to in Article 27(2), assign a Basic UDI-DI as defined in Part C of Annex VI to the device and shall provide it to the UDI database together with the other core data elements referred to in Part B of Annex VI related to that device."

Source: Regulation (EU) 2017/745 (MDR), Article 29, first paragraph.

The steps are in the articles on EUDAMED device registration and EUDAMED registration, what the Basic UDI-DI is, and legacy device registration for products with old certificates; the device name on the Bulgarian label is kept the same as the trade name in EUDAMED (EUDAMED registration consultancy).

 

Language Requirement for Bulgaria: Label, IFU and Patient Information

The overarching basis for the Bulgarian requirement is the MDR's language provision:

"Manufacturers shall ensure that the device is accompanied by the information set out in Section 23 of Annex I in an official Union language(s) determined by the Member State in which the device is made available to the user or patient. The particulars on the label shall be indelible, easily legible and clearly comprehensible to the intended user or patient."

Source: MDR Article 10(11), Regulation (EU) 2017/745.

The Commission's language requirements table (Rev. 3, August 2025) marks the Bulgaria row with an asterisk for up-to-date information.

In the Commission table, the Bulgaria row reads: label and IFU in Bulgarian for both patient and professional users; basis: Medical Devices Act (12 June 2007) Article 28 paragraph 2 item 4. The row is marked with an asterisk, meaning a recent update has not reached the Commission. In the table, the implant card, declaration of conformity and field safety notice columns are empty for Bulgaria; we do not state a national language requirement for these columns.

Result for a Turkish manufacturer: the label and IFU are in Bulgarian, and the table has no English exception for professional users. Typesetting in Cyrillic narrows the packaging area; using symbols (ISO 15223-1) shortens the text but does not remove the mandatory Bulgarian information. Giving the relationship of the Bulgarian device name to the trade name in EUDAMED on the first page of the IFU makes matching easier for BDA and the importer. You can keep the declaration of conformity in English; the table has no requirement for a Bulgarian translation.

 

Competent Authority: BDA

The competent authority in Bulgaria is the Изпълнителна агенция по лекарствата (BDA, Bulgarian Drug Agency); in the Commission's May 2026 list the address is given as Damyan Gruev 8, Sofia, and the contact as bda@bda.bg. The medical device pages are on bda.bg under 'Information for companies > Medical devices' and there is also an English version.

The BDA 'Forms' page lists six documents: the application for registration of manufacturers and IVD devices (Medical Devices Act Art. 28(1) and (3)), the application for registration of manufacturers and devices supplied to the Bulgarian market (Art. 27(1)), the information form for devices put into service in Bulgaria (Art. 30), the IVD notification form, the instruction for preparing the device list and the document on device categories. The names of the forms are published in Bulgarian and English. The page does not explain which economic operator (a manufacturer established in Bulgaria, an authorised representative or an importer) these obligations fall on; we also do not write 'applies' or 'does not apply' for a Turkish manufacturer. Your Bulgarian importer clarifies with BDA which form will be submitted in its own name; what is asked of you as the manufacturer is the EUDAMED registration, the declaration of conformity, the certificate if any, the label and the IFU.

Bulgarian public hospitals and tender authorities often ask in the file for a free sale certificate and the manufacturer's declaration of conformity in apostilled or e-signed form; these documents are prepared in Türkiye and a Bulgaria-specific FSC is obtained through ÜTS. Since BDA's forms ask for devices in list form (Spisaci_mi instruction), giving the Bulgarian importer the product name, model and barcode list from ÜTS in the same structure speeds up the file.

For shipments to Bulgaria by road, the customs declaration is closed at Kapıkule; the declaration number to be written in the ÜTS export notification is this declaration. If the shipment goes through a bonded warehouse or free zone, the notification chain changes; we explain this in the ÜTS section below.

 

Appointing an Authorised Representative Is Not Required for the Bulgarian Market

MDR Article 11(1) requires an authorised representative for a manufacturer established outside the Union; Türkiye is not outside the Union in this article, and the basis is the Medical Device Regulation:

"Where the manufacturer is not established in Türkiye or an EU member state, the device may be placed on the market only on the condition that the manufacturer appoints an authorised representative."

Source: Medical Device Regulation, Article 11(1).

The TİTCK translation of MDCG 2022-16 also treats Türkiye as part of the Union market through the Customs Union:

"'Union market' refers to the territories of the Member States of the European Union and, owing to the European Economic Area (EEA), is extended to Norway, Liechtenstein and Iceland, and through the Customs Union Agreement to Türkiye."

Source: MDCG 2022-16 Guidance on Authorised Representatives, TİTCK translation, first footnote.

The Commission's March 2022 notice states the same result; even if BDA forms come up, a Turkish manufacturer needs no AR contract, no label with an AR address and no AR SRN. The authorised representative obligation for imports into Türkiye is covered in this article.

 

ÜTS Export Notification for a Product Leaving via Edirne

For individually tracked products leaving by road via Edirne, the Turkish side is closed by the following provision:

"An 'Export Notification' is made for individually tracked products exported by the company."

"When making an Export Notification in ÜTS, after querying with the product number, lot and/or serial number,"

Source: Guide on Individual Movement Notifications of the Product Tracking System for Medical Devices (TİTCK), Article 17.

After the customs declaration is closed, the declaration number and quantity are entered; a wrong notification is corrected with an 'Export Cancellation Notification' (Article 17/3).

A consignment going directly over the land border has no bonded warehouse chain; shipments via a free zone or bonded warehouse are covered in a separate article, with all types in individual movement notifications and monthly service individual notification operations.

Free Sale Certificate for Bulgaria

If the Bulgarian buyer asks for a free sale certificate, TİTCK issues the document under Medical Device Regulation Article 60/1; only Bulgaria is selected in the country field of the ÜTS application (Registration Guide Article 42) and the certificate cannot be used for another market. The steps are in the free sale certificate article.

 

Bulgaria Summary Table

 

TopicStatusCompetent authorityBDA - Изпълнителна агенция по лекарствата (Bulgarian Drug Agency), Sofia; bda.bgLabel / IFU languageBulgarian (patient and professional user; Medical Devices Act Art. 28 paragraph 2 item 4). Bulgaria is marked with an asterisk in the Commission table for up-to-date information.National additional registration / notificationBDA publishes the manufacturer/device registration and putting-into-service notification forms under Medical Devices Act Art. 27(1), 28(1)-(3) and 30. Whether these forms apply to a manufacturer established in Türkiye could not be confirmed from the BDA site; it is clarified with the Bulgarian importer/distributor.Is an AR requiredNo; Medical Device Regulation Article 11/1 and MDCG 2022-16 footnote 1 treat Türkiye as part of the Union marketEUDAMED / ÜTSSRN and Basic UDI-DI registration are the only registration the Bulgarian importer looks for; in ÜTS, the export notification after the land exit, and the free sale certificate on request

 

Other markets in the Balkans and Central Europe

Exporting medical devices to Romania

Exporting medical devices to Greece

Exporting medical devices to Croatia

Exporting medical devices to Hungary

 

Medical Device ÜTS Registration Consultancy for exports to Bulgaria

EUDAMED registrations, ÜTS notifications, free sale certificate and sworn translation are within Medex's scope when preparing for Bulgaria. Request a quote, call +90 505 580 46 22 or write to info@medexmedikal.com.

Frequently Asked Questions

Is an English label accepted for professional use in Bulgaria?

According to the Commission's language table, no: in Bulgaria the label and IFU are in Bulgarian for both patient and professional users (Medical Devices Act Art. 28 paragraph 2 item 4).

Is manufacturer registration with BDA mandatory for a Turkish company?

The BDA site publishes the registration forms under Art. 27(1) and 28, but does not explain whether these forms apply to a manufacturer established in Türkiye. The Bulgarian importer clarifies this point with BDA; on the manufacturer side, EUDAMED actor and device registration is required in every case.

Do I need to appoint an EU authorised representative for Bulgaria?

You do not need to appoint one. Article 11/1 of the Medical Device Regulation treats Türkiye and EU member states as a single area; MDCG 2022-16 footnote 1 and the Commission's March 2022 notice keep the Turkish manufacturer outside the authorised representative obligation. For a consignment leaving via Edirne, what is looked for is the EUDAMED SRN and a Bulgarian label, not an authorisation document.

How is the ÜTS notification made for a product leaving by road from Edirne?

After the customs declaration is closed, for products under individual tracking the export notification is made by entering the declaration number and quantity. In case of error, the export cancellation notification is used.

Is EUDAMED device registration mandatory for Bulgaria?

Yes. The actor and UDI/device registration modules have been mandatory since 28 May 2026; a Bulgarian importer wants to see the device in EUDAMED. Registration is made with the Basic UDI-DI and Annex VI Part B data.

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.

bottom of page
WhatsApp Hemen Ara