ÜTS Document Type: User Manual (Turkish Instructions for Use)

The user manual is the device's instructions for use and is prepared by its manufacturer in accordance with the provisions of the medical device regulations. Its content is determined under the General Safety and Performance Requirements section (Annex I) of the regulation covering the device; the label and instructions for use requirements are set out in section 23 of Annex I of the Medical Device Regulation. For devices placed on the market in Turkey, the manual must be in Turkish. In ÜTS, the manual is a mandatory document for certain risk classes and optional for others. For manuals provided electronically rather than on paper, the same document registration and update notification is made. Who prepares the document: The manual is prepared by the manufacturer of the device. For devices that are accessories, if the manufacturer of the main device differs from the manufacturer of the accessory, the accessory's own manual is uploaded if there is one; if not, the manual prepared by the manufacturer of the main device is uploaded, without regard to criteria such as notified body and address differences. For systems and procedure packs, if the SPP manufacturer has prepared a separate manual, the package's own manual is uploaded; if not, all manuals of the devices in the package that fall within the regulation are uploaded. For which products it is required: Uploading the manual is mandatory for Class III and Class IIb devices certified under MDR and MDD. For Class IIa devices, the manual is uploaded if the manufacturer has prepared one; only for Class IIa devices under MDD for which the manufacturer has not prepared a manual, an Intended Use Form/Declaration is uploaded instead. The manual is also mandatory for Class B, Class C and Class D devices under IVDR, including Self-Test Devices (Class B/C/D), Near-Patient Test Devices (Class B/C/D) and Companion Diagnostic Devices (Class C/D); for Annex II List A or Annex II List B devices and Self-Test Devices under IVDD; and for devices under AIMDD. Uploading is optional for Class I Other, Class Im, Class Is, Class Ir, Class A, Class A Sterile and IVD Other devices; the Authority may also request a manual for these groups where it deems it necessary. No manual upload obligation applies to Class IIa devices marked as components or accessories. Fields completed in the ÜTS document record: • Name or trade name and address of the manufacturer and, if any, of the EU authorized representative • Product scope information for the user that describes the contents of the package and the device • Intended purpose foreseen by the manufacturer • Print date and, if updated, the latest update information: update date, revision number • CE marking together with the four-digit notified body number; for Class I Other, Class A and IVD Other products the CE marking alone is sufficient, and no CE marking is required for SPP-specific manuals • Name or trade name of the device • Registered trade name or registered trade mark of the manufacturer and registered place of business address • If the device is supplied sterile, an indication of its sterile condition and sterilization method • If single-use, the "Single Use" statement • If sterilization is required before use, the sterilization method and details • For reusable devices, validated methods for cleaning, disinfection, packaging and re-sterilization • Any special storage and handling conditions. In importer notifications, if the original manual is not in Turkish, the most current original manual in the technical file is uploaded to the "Original Document" field and its Turkish translation to the "Turkish Document" field. If the manual was prepared in multiple languages including Turkish, the "Is the Original Document Turkish?" option is set to "Yes" and all pages of the multilingual manual are uploaded. If the manufacturer prepared the manual in Turkish, the most current manual prepared in at least one of the official EU languages is uploaded to the "Original Document" field and the Turkish manual to the "Turkish Document" field. Domestic manufacturers upload the most current Turkish manual. When it is not accepted: A manual is not accepted if it is submitted with missing pages or with only part of a multilingual manual uploaded. If the manual has been updated but neither the update date nor the update information is entered in ÜTS, the notification is not completed. If the print or update date in the manual is given as month and year, the day is entered in ÜTS as "1"; for example, 01.05.2020 is entered for 05/2020. In mandatory classes, uploading a catalog or promotional document instead of the manual is not accepted. Common mistakes: • Uploading an old manual version instead of the most current version in the technical file • When two different original manuals are uploaded, entering in the "Print/Update Information" field the details of the older-dated document • Skipping the manual obligation entirely for accessory devices • Leaving the CE marking and notified body number in the manual inconsistent with the certificate information in the device record. Who it concerns: Manufacturers, importers and authorized representatives who make device and document registrations in ÜTS, and companies preparing Turkish manuals. Common mistake: Uploading an outdated manual or one with missing pages and not entering the update information into the system. Basis: Guideline on the Registration Processes of Medical Devices in the Product Tracking System (TCKKD-KLVZ-03, in force 13.05.2026) Articles 17, 18 and 39; Medical Device Regulation (OG 02.06.2021-31499 bis) Annex I section 23.

Medical Device ÜTS Registration Consultancy

Request an ÜTS registration consultancy quote

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.

bottom of page
WhatsApp Hemen Ara