When Is a Supply Interruption Notified?

A supply interruption or discontinuation is notified, except in exceptional circumstances, at least six months before the anticipated interruption or discontinuation.

ÜTS frequently asked questions: When Is a Supply Interruption Notified?

A supply interruption or discontinuation is notified, except in exceptional circumstances, at least six months before the anticipated interruption or discontinuation. The notification is made by the manufacturer, who informs the Agency as well as the economic operators, healthcare institutions and healthcare professionals to which it directly supplies the device. The provision is in Article 10/A, added to the Medical Device Regulation by the amendment dated 17.08.2024.

When the notification obligation arises

The obligation applies to devices other than custom-made devices. Notification is made where the manufacturer anticipates an interruption or discontinuation in the supply of a device and it is reasonably foreseeable that this interruption or discontinuation could result in serious harm or a risk of serious harm to patients or public health in Türkiye or in one or more EU member states. In other words, not every supply fluctuation is covered, but interruptions and discontinuations where serious harm or a risk of serious harm is reasonably foreseeable.

To whom and when it is notified

  • The manufacturer informs the Agency of the anticipated interruption or discontinuation
  • The manufacturer also informs the economic operators, healthcare institutions and healthcare professionals to which it directly supplies the device
  • Except in exceptional circumstances, this information is provided at least six months before the anticipated interruption or discontinuation
  • The manufacturer clearly states the reasons for the interruption or discontinuation in the information provided to the Agency
  • After receiving the information, the Agency informs the competent authorities of the other EU member states and the Commission of the anticipated interruption or discontinuation without delay

Passing information along the supply chain

Economic operators that receive information from the manufacturer or from another economic operator in the supply chain inform the other economic operators, healthcare institutions and healthcare professionals to which they directly supply the device of the anticipated interruption or discontinuation without delay. In this way the information is carried from the manufacturer to the user at the end of the chain. Economic operator means the manufacturer, the authorised representative, the importer, the distributor, or the person referred to in the first and third paragraphs of Article 22 of the Regulation.

Link with traceability

Being able to identify the parties to which the notification must be delivered depends on supply chain records being kept properly. Economic operators must be able to identify to the Agency every economic operator to which they have directly supplied a device, every economic operator that has directly supplied them, and every healthcare institution or healthcare professional to which they have directly supplied the device. Distributors and importers cooperate with manufacturers or authorised representatives to achieve an appropriate level of traceability of devices. On the sales side, sales centres keep a record of the name, trade title or brand and contact details of the preceding and, if any, the following economic operator in the supply chain, and other information that will facilitate tracking of the devices, by parameters such as batch, serial, lot, brand and model, and retain these records for at least ten years from the date they started to make the device available on the market.

Common mistakes

  • Notifying only the Agency and not informing the healthcare institutions and healthcare professionals directly supplied
  • Calculating the six-month period back from the date the decision was taken rather than from the date the interruption actually starts
  • Not clearly stating the reasons for the interruption in the notification to the Agency
  • An economic operator in the middle of the chain skipping the obligation to pass on the information received to its own customers

Who it concerns: Manufacturers, authorised representatives, importers, distributors, sales centres, procurement units of healthcare institutions and healthcare professionals. İmalatçılar, yetkili temsilciler, ithalatçılar, dağıtıcılar, satış merkezleri, sağlık kuruluşlarının satın alma birimleri ve sağlık profesyonelleri.

Common mistake: Missing the six-month advance notice period and announcing the interruption only when stock runs out. Altı aylık ön bildirim süresini kaçırıp kesintiyi ancak stok tükendiğinde duyurmak.

Basis: Medical Device Regulation (OG 02.06.2021-31499 bis) ARTICLE 3, ARTICLE 10/A (Added: OG 17.08.2024-32635), ARTICLE 25; Medical Device Sales, Advertising and Promotion Regulation (OG 15.05.2014-29001) ARTICLE 31. Tıbbi Cihaz Yönetmeliği (RG 02.06.2021-31499 mükerrer) MADDE 3, MADDE 10/A (Ek: RG 17.08.2024-32635), MADDE 25; Tıbbi Cihaz Satış, Reklam ve Tanıtım Yönetmeliği (RG 15.05.2014-29001) MADDE 31.

Notification and Follow-up

Medical Device ÜTS Registration Consultancy

Request an ÜTS registration consultancy quote

Ehlibeyt Mahallesi, Tekstilciler Caddesi No: 35/7 06520 Çankaya / Ankara - TÜRKİYE

Cevizli Mahallesi, Zuhal Caddesi Ritim İstanbul B Blok, No:44 Maltepe / İstanbul - TÜRKİYE

info@medexmedikal.com
+90 505 580 4622
+90 312 389 1354

ÜTS Guides · Legislation Calendar · Glossary · ÜTS Guide Index · Frequently Asked Questions

Services: ÜTS Consultancy · Who Carries Out the ÜTS Registration? · ÜTS Document Registration Consultancy · ÜTS Product Registration Consultancy · Importer ÜTS Registration Consultancy · Sales Centre Authorisation Certificate · EUDAMED Registration Consultancy · MDR/IVDR Declaration of Conformity · Technical File Preliminary Review · Label and Instructions for Use Check · PRRC Service · PMS and PSUR · Clinical Evaluation · EMDN and GMDN Code Determination · Certificate of Free Sale · EUDAMED XML Generator · ÜTS Registration Training · Correction of a Rejected ÜTS Application

KVKK and Privacy Policy | Cookie Policy | Accessibility Statement

© 2026 Medex Kurumsal Danışmanlık Ltd. Şti.

bottom of page
WhatsApp Hemen Ara